GLOBAL AND REGIONAL VARIATIONS IN THE SPINAL TRABECULAR BONE - SINGLE AND DUAL ENERGY EXAMINATIONS

被引:28
作者
SANDOR, T
FELSENBERG, D
KALENDER, WA
BROWN, E
机构
[1] HARVARD UNIV, BRIGHAM & WOMENS HOSP, SCH MED, DEPT ENDOCRINOL, BOSTON, MA 02115 USA
[2] FREE UNIV BERLIN, KLINIKUM STEGLITZ, DEPT RADIOL, W-1000 BERLIN 45, GERMANY
[3] SIEMENS MED SYST INC, ERLANGEN, GERMANY
关键词
D O I
10.1210/jcem-72-5-1157
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Two hundred and sixty-eight vertebrae from 92 subjectgs (42 males and 50 females) were used to assess inter- and intravertebral variations in the mineral content of spinal trabecular bone from L1-L3. Using a computer-generated grid superimposed on the trabecular bone, the spatial distribution of the mineral content was computed for 48 subdivisions of the grid for single and dual energy computed tomographic examinations. In addition, the age dependence of the mineral content was assessed by regression analysis from each subdivision. The results demonstrated a nonhomogenous distribution of mineral density within the trabecular bone. The lateral and anterolateral subcortical regions show significantly lower mineral density than the posterolateral or anterior subcortical domains. Moreover, with increasing age, bone density was also lost in a nonuniform fashion. Finally, the analysis of regional intervertebral change for the L1-L3 vertebrae revealed a nonhomogenous pattern of mineral distribution.
引用
收藏
页码:1157 / 1168
页数:12
相关论文
共 14 条
[1]   ENERGY-SELECTIVE RECONSTRUCTIONS IN X-RAY COMPUTERIZED TOMOGRAPHY [J].
ALVAREZ, RE ;
MACOVSKI, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1976, 21 (05) :733-744
[2]  
BAKER SP, 1985, CLIN GERIATR MED, V1, P1
[3]  
CANN CE, 1980, JAMA-J AM MED ASSOC, V244, P2056
[4]   THE DIRECT EXAMINATION OF 3-DIMENSIONAL BONE ARCHITECTURE INVITRO BY COMPUTED-TOMOGRAPHY [J].
FELDKAMP, LA ;
GOLDSTEIN, SA ;
PARFITT, AM ;
JESION, G ;
KLEEREKOPER, M .
JOURNAL OF BONE AND MINERAL RESEARCH, 1989, 4 (01) :3-11
[5]   VERTEBRAL BONE-MINERAL ANALYSIS - AN INTEGRATED APPROACH WITH CT [J].
KALENDER, WA ;
KLOTZ, E ;
SUESS, C .
RADIOLOGY, 1987, 164 (02) :419-423
[6]   EVALUATION OF A PROTOTYPE DUAL-ENERGY COMPUTED TOMOGRAPHIC APPARATUS .1. PHANTOM STUDIES [J].
KALENDER, WA ;
PERMAN, WH ;
VETTER, JR ;
KLOTZ, E .
MEDICAL PHYSICS, 1986, 13 (03) :334-339
[7]   A NEW CALIBRATION PHANTOM FOR QUANTITATIVE COMPUTED-TOMOGRAPHY [J].
KALENDER, WA ;
SUESS, C .
MEDICAL PHYSICS, 1987, 14 (05) :863-866
[8]   PERFORMANCE EVALUATION OF A DUAL-ENERGY X-RAY BONE DENSITOMETER [J].
MAZESS, R ;
COLLICK, B ;
TREMPE, J ;
BARDEN, H ;
HANSON, J .
CALCIFIED TISSUE INTERNATIONAL, 1989, 44 (03) :228-232
[9]  
MAZESS RB, 1988, J BONE MINER RES, V3, P13
[10]   RELATIONSHIPS BETWEEN SURFACE, VOLUME, AND THICKNESS OF ILIAC TRABECULAR BONE IN AGING AND IN OSTEOPOROSIS - IMPLICATIONS FOR THE MICROANATOMIC AND CELLULAR MECHANISMS OF BONE LOSS [J].
PARFITT, AM ;
MATHEWS, CHE ;
VILLANUEVA, AR ;
KLEEREKOPER, M ;
FRAME, B ;
RAO, DS .
JOURNAL OF CLINICAL INVESTIGATION, 1983, 72 (04) :1396-1409