DIRECT ANALYSIS OF STEELS BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY WITH A CW Q-SWITCHED ND-YAG LASER

被引:5
作者
MOCHIZUKI, T
SAKASHITA, A
TSUJI, T
IWATA, H
ISHIBASHI, Y
GUNJI, N
机构
[1] NKK Corp, Kawasaki
来源
TETSU TO HAGANE-JOURNAL OF THE IRON AND STEEL INSTITUTE OF JAPAN | 1991年 / 77卷 / 11期
关键词
LASER ABLATION; INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY; CW Q-SWITCHED ND-YAG LASER; STEELS; TRACE ELEMENTAL ANALYSIS;
D O I
10.2355/tetsutohagane1955.77.11_1851
中图分类号
TF [冶金工业];
学科分类号
0806 ;
摘要
A cw Q-switched Nd:YAG laser has been applied to a laser ablation system for the direct analysis of steels by inductively coupled plasma mass spectrometry (ICP-MS). The YAG laser used produced fine particles (particles size, about 0.02-mu-m) at relatively high ablation rate (maximum 22-mu-g s-1); and that was important feature to improve sensitivity and precision. Selective vaporization of volatile elements was occurred in the ablation process, but the magnitude was low. The use of iron as an internal standard was effective to improve accuracy and precision. Good accuracy was obtained for trace elements such as B, As, Nb, Sn and so on. On the other hand, precision ranged from 5 to 10 (RSD, %) for the most of elements (isotope contents, 10 approximately 200-mu-g g-1). Detection of Si, Al and P were problematic due to molecular interferences and some contaminations in ICP-MS measurement. But the limits of other 14 elements were excellent (0.01-mu-g g-1 for Nd approximately 5.6-mu-g g-1 for Ni at the effective integrating time of 0.18 s). It was found that the laser ablation analysis without standards has enough accuracy to apply semiquantitative analysis.
引用
收藏
页码:1851 / 1858
页数:8
相关论文
共 19 条
[1]   ELECTRONIC EXCITATION AND IONIZATION TEMPERATURE-MEASUREMENTS IN A HIGH-FREQUENCY INDUCTIVELY COUPLED ARGON PLASMA SOURCE AND THE INFLUENCE OF WATER-VAPOR ON PLASMA PARAMETERS [J].
ALDER, JF ;
BOMBELKA, RM ;
KIRKBRIGHT, GF .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1980, 35 (04) :163-175
[2]   LASER ABLATION OF SOLIDS FOR ELEMENTAL ANALYSIS BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
ARROWSMITH, P .
ANALYTICAL CHEMISTRY, 1987, 59 (10) :1437-1444
[3]  
BLANKENBURG LM, 1989, CHEM ANAL, V105
[4]  
DITTRICH K, 1984, PROG ANAL ATOM SPECT, V7, P139
[7]   ATOMIC EMISSION-SPECTROMETRY OF SOLID SAMPLES WITH LASER VAPORIZATION MICROWAVE INDUCED PLASMA SYSTEM [J].
ISHIZUKA, T ;
UWAMINO, Y .
ANALYTICAL CHEMISTRY, 1980, 52 (01) :125-129
[8]   INDUCTIVELY COUPLED PLASMA EMISSION-SPECTROMETRY OF SOLID SAMPLES BY LASER ABLATION [J].
ISHIZUKA, T ;
UWAMINO, Y .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1983, 38 (03) :519-527
[9]  
KAWAGUCHI H, 1982, BUNSEKI KAGAKU, V31, pE185
[10]   DIRECT DETERMINATION OF COPPER IN SOLIDS BY DIRECT-CURRENT ARGON PLASMA EMISSION-SPECTROMETRY WITH SAMPLE INTRODUCTION USING LASER ABLATION [J].
MITCHELL, PG ;
SNEDDON, J ;
RADZIEMSKI, LJ .
APPLIED SPECTROSCOPY, 1987, 41 (01) :141-148