HOLTER DOCUMENTED SUDDEN-DEATH IN A PATIENT WITH AN IMPLANTED DEFIBRILLATOR

被引:29
作者
BIRGERSDOTTERGREEN, U
ROSENQVIST, M
LINDEMANS, FW
RYDEN, L
RADEGRAN, K
机构
[1] KAROLINSKA HOSP,DEPT CARDIOL,CLIN CLIN,S-10401 STOCKHOLM 60,SWEDEN
[2] BAKKEN RES CTR,MAASTRICHT,NETHERLANDS
[3] KAROLINSKA HOSP,DEPT THORAC SURG,S-10401 STOCKHOLM 60,SWEDEN
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1992年 / 15卷 / 07期
关键词
SUDDEN DEATH; IMPLANTABLE CARDIOVERTER DEFIBRILLATOR;
D O I
10.1111/j.1540-8159.1992.tb03094.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A 68-year-old man with recurrent attacks of monomorphic ventricular tachycardia [VT] received a pacer cardioverter defibrillator featuring antitachycardia pacing and cardioversion/defibrillation. Over 300 episodes of VT were successfully terminated by antitachycardia pacing. During Holter monitoring the patient experienced supraventricular tachycardia with delivery of multiple antitachycardia pacing, cardioversion, and defibrillation therapies ending with the death of the patient. The following factors played a role in the unfortunate outcome of this patient: 1. triggering of VT therapy by an unexpected high sinus rate; 2. atrial fibrillation induced by cardioversion therapy; 3. a gradual and continuous increase in rate during atrial fibrillation possibly caused by repeated VT and ventricular fibrillation therapies and/or by a thrombus, found at autopsy, in a bypass graft; and 4. the limited ability of presently available defibrillators to distinguish between ventricular and supraventricular arrhythmias.
引用
收藏
页码:1008 / 1014
页数:7
相关论文
共 8 条
  • [1] IMPLANTABLE CARDIOVERTER DEFIBRILLATOR PROARRHYTHMIA - CASE-REPORT AND REVIEW OF THE LITERATURE
    COHEN, TJ
    CHIEN, WW
    LURIE, KG
    LEE, MA
    LESH, MD
    SCHEINMAN, MM
    GRIFFIN, JC
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1991, 14 (09): : 1326 - 1329
  • [2] ACTUARIAL INCIDENCE AND PATTERN OF OCCURRENCE OF SHOCKS FOLLOWING IMPLANTATION OF THE AUTOMATIC IMPLANTABLE CARDIOVERTER DEFIBRILLATOR
    FOGOROS, RN
    ELSON, JJ
    BONNET, CA
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1989, 12 (09): : 1465 - 1473
  • [3] KATZ A, 1990, Journal of the American College of Cardiology, V15, p52A
  • [4] THE AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR - EFFICACY, COMPLICATIONS AND SURVIVAL IN PATIENTS WITH MALIGNANT VENTRICULAR ARRHYTHMIAS
    KELLY, PA
    CANNOM, DS
    GARAN, H
    MIRABAL, GS
    HARTHORNE, JW
    HURVITZ, RJ
    VLAHAKES, GJ
    JACOBS, ML
    ILVENTO, JP
    BUCKLEY, MJ
    RUSKIN, JN
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1988, 11 (06) : 1278 - 1286
  • [5] THE AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR - EFFICACY, COMPLICATIONS, AND DEVICE FAILURES
    MARCHLINSKI, FE
    FLORES, BT
    BUXTON, AE
    HARGROVE, WC
    ADDONIZIO, VP
    STEPHENSON, LW
    HARKEN, AH
    DOHERTY, JU
    GROGAN, EW
    JOSEPHSON, ME
    [J]. ANNALS OF INTERNAL MEDICINE, 1986, 104 (04) : 481 - 488
  • [6] THE AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR - AN OVERVIEW
    MIROWSKI, M
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1985, 6 (02) : 461 - 466
  • [7] SPONTANEOUS CHANGES IN VENTRICULAR-TACHYCARDIA CYCLE LENGTH
    VOLOSIN, KJ
    BEAUREGARD, LAM
    FABISZEWSKI, R
    MATTINGLY, H
    WAXMAN, HL
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 17 (02) : 409 - 414
  • [8] IMPORTANCE OF MODES OF ELECTRICAL TERMINATION OF VENTRICULAR-TACHYCARDIA FOR THE SELECTION OF IMPLANTABLE ANTITACHYCARDIA DEVICES
    WALDECKER, B
    BRUGADA, P
    ZEHENDER, M
    STEVENSON, W
    DENDULK, K
    WELLENS, HJJ
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1986, 57 (01) : 150 - 155