CHARACTERISTICS OF A DIODE-BRIDGE-LOADED SYNCHRONOUS GENERATOR WITHOUT DAMPER WINDINGS

被引:7
作者
BONWICK, WJ [1 ]
机构
[1] MONASH UNIV,DEPT ELECT ENGN,CLAYTON 3168,VICTORIA,AUSTRALIA
来源
PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON | 1975年 / 122卷 / 06期
关键词
D O I
10.1049/piee.1975.0173
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The paper extends the theoretical study of diode-bridge-loaded synchronous generators without damper windings to loads with commutation angles equal to or greater than 60 degree (modes 2 and 3). The equations necessary to establish the performance in these operating modes, and a simple method of establishing the boundaries between the modes, are given. Constant flux linkages are assumed. Experimental results from tests on a 5 kva laboratory generator have been used to check the computed theoretical results obtained by using the published equations. A larger turbogenerator exciter has been used to illustrate the theoretical difference between operation in mode 1 and mode 2.
引用
收藏
页码:637 / 642
页数:6
相关论文
共 3 条
[1]   RECTIFIER-LOADED SYNCHRONOUS GENERATORS WITH DAMPER WINDINGS [J].
BONWICK, WJ ;
JONES, VH .
PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1973, 120 (06) :659-666
[2]  
FRERIS LL, 1963, DIRECT CURRENT, V8, P6
[3]  
HAWLEY R, 1974, CIGRE, P1