COMPARISON OF MEASUREMENT VARIABILITY USING A STANDARD AND CONSTANT FORCE PERIODONTAL PROBE

被引:87
作者
OSBORN, J [1 ]
STOLTENBERG, J [1 ]
HUSO, B [1 ]
AEPPLI, D [1 ]
PIHLSTROM, B [1 ]
机构
[1] UNIV MINNESOTA,CLIN RES CTR PERIODONTAL DIS,MINNEAPOLIS,MN 55455
关键词
D O I
10.1902/jop.1990.61.8.497
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study compared the intra- and inter-examiner reliability of the Florida Probe, Florida Disk Probe, and conventional periodontal probe. Using these instruments, each of three examiners made repeated measurements of probing depth (using the Florida Probe and conventional probe), relative attachment level (using the Florida Disk Probe), and clinical attachment level (using a conventional probe) at posterior, proximal sites in 10 subjects with early periodontitis. The mean intra-examiner standard deviation of differences in repeated probing depth measurements ranged from 0.46 to 0.77 mm demonstrating similar levels of reproducibility between the Florida Probe and conventional probe. The mean intra-examiner standard deviation of differences in repeated relative attachment level measurements using the Florida Disk Probe ranged from 0.44 to 0.57 mm using double passes and from 0.98 to 1.41 mm using single passes of measurements. For clinical attachment level measurements obtained using single passes of measurements with a conventional probe, the mean intra-examiner standard deviation of differences ranged from 0.78 to 0.95 mm. Inter-examiner variability was generally greater than intra-examiner variability for all instruments. It was concluded that double passes with the Florida Disk Probe offers significant advantages for measuring relative attachment level in longitudinal studies of early periodontitis when decisions for change must be made as soon as possible.
引用
收藏
页码:497 / 503
页数:7
相关论文
共 13 条
  • [1] REPRODUCIBILITY OF PROBING ATTACHMENT LEVEL MEASUREMENTS
    BADERSTEN, A
    NILVEUS, R
    EGELBERG, J
    [J]. JOURNAL OF CLINICAL PERIODONTOLOGY, 1984, 11 (07) : 475 - 485
  • [2] EVALUATION OF PERIODONTAL PROBING FORCES
    FREED, HK
    GAPPER, RL
    KALKWARF, KL
    [J]. JOURNAL OF PERIODONTOLOGY, 1983, 54 (08) : 488 - 492
  • [3] DESCRIPTION AND CLINICAL-EVALUATION OF A NEW COMPUTERIZED PERIODONTAL PROBE - THE FLORIDA PROBE
    GIBBS, CH
    HIRSCHFELD, JW
    LEE, JG
    LOW, SB
    MAGNUSSON, I
    THOUSAND, RR
    YERNENI, P
    CLARK, WB
    [J]. JOURNAL OF CLINICAL PERIODONTOLOGY, 1988, 15 (02) : 137 - 144
  • [4] GLAVIND LEIF, 1967, J PERIODONTAL RES, V2, P180, DOI 10.1111/j.1600-0765.1967.tb01887.x
  • [5] COMPARISON OF DIFFERENT DATA ANALYSES FOR DETECTING CHANGES IN ATTACHMENT LEVEL
    HAFFAJEE, AD
    SOCRANSKY, SS
    GOODSON, JM
    [J]. JOURNAL OF CLINICAL PERIODONTOLOGY, 1983, 10 (03) : 298 - 310
  • [6] COMPARISON OF MANUAL AND PRESSURE-CONTROLLED PERIODONTAL PROBING
    KALKWARF, KL
    KALDAHL, WB
    PATIL, KD
    [J]. JOURNAL OF PERIODONTOLOGY, 1986, 57 (08) : 467 - 471
  • [7] CORRELATION BETWEEN ELECTRONIC AND VISUAL READINGS OF POCKET DEPTHS WITH A NEWLY DEVELOPED CONSTANT FORCE PROBE
    MAGNUSSON, I
    FULLER, WW
    HEINS, PJ
    RAU, CF
    GIBBS, CH
    MARKS, RG
    CLARK, WB
    [J]. JOURNAL OF CLINICAL PERIODONTOLOGY, 1988, 15 (03) : 180 - 184
  • [8] ATTACHMENT LEVEL MEASUREMENTS WITH A CONSTANT FORCE ELECTRONIC PROBE
    MAGNUSSON, I
    CLARK, WB
    MARKS, RG
    GIBBS, CH
    MANOUCHEHRPOUR, M
    LOW, SB
    [J]. JOURNAL OF CLINICAL PERIODONTOLOGY, 1988, 15 (03) : 185 - 188
  • [9] VALIDITY OF A HINGED CONSTANT FORCE PROBE AND A SIMILAR, IMMOBILIZED PROBE IN UNTREATED PERIODONTAL-DISEASE
    SIMONS, P
    WATTS, T
    [J]. JOURNAL OF CLINICAL PERIODONTOLOGY, 1987, 14 (10) : 581 - 587
  • [10] VANDERVELDEN U, 1978, J CLIN PERIODONTOL, V5, P188