DESIGN OF IONOPHORE-FREE H+-SELECTIVE SOLVENT POLYMERIC MEMBRANES FOR FURTHER BIOMEDICAL APPLICATIONS

被引:40
作者
COSOFRET, VV
LINDNER, E
BUCK, RP
KUSY, RP
WHITLEY, JQ
机构
[1] UNIV N CAROLINA,DEPT CHEM,CHAPEL HILL,NC 27599
[2] UNIV N CAROLINA,DEPT ORTHODONT,CHAPEL HILL,NC 27599
来源
JOURNAL OF ELECTROANALYTICAL CHEMISTRY | 1993年 / 345卷 / 1-2期
关键词
D O I
10.1016/0022-0728(93)80477-Y
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Ionophore-free H+-selective solvent polymeric membrane electrodes based on aminated poly(vinyl chloride) (PVC-NH2) are studied. Among the large number of amino-PVC derivatives, the electrodes fabricated from piperazine-modified PVC show the best analytical performances. The new pH electrodes exhibit a Nernstian response between pH 4 and pH 12, and their selectivity coefficients toward biologically interesting cations match the corresponding values of H+ electrodes based on TDDA or ETH 5294. The.new membrane material offers additional prospects for ion-selective electrode fabrication with technologies used in microelectronic device development.
引用
收藏
页码:169 / 181
页数:13
相关论文
共 29 条
  • [1] LIPOPHILIC SALTS AS MEMBRANE ADDITIVES AND THEIR INFLUENCE ON THE PROPERTIES OF MACROELECTRODES AND MICROELECTRODES BASED ON NEUTRAL CARRIERS
    AMMANN, D
    PRETSCH, E
    SIMON, W
    LINDNER, E
    BEZEGH, A
    PUNGOR, E
    [J]. ANALYTICA CHIMICA ACTA, 1985, 171 (MAY) : 119 - 129
  • [2] NEUTRAL CARRIER BASED HYDROGEN-ION SELECTIVE MICROELECTRODE FOR EXTRACELLULAR AND INTRACELLULAR STUDIES
    AMMANN, D
    LANTER, F
    STEINER, RA
    SCHULTHESS, P
    SHIJO, Y
    SIMON, W
    [J]. ANALYTICAL CHEMISTRY, 1981, 53 (14) : 2267 - 2269
  • [3] AMMANN D, 1986, ION SELECTIVE MICROE, pCH18
  • [4] BAILEY PL, 1980, ANAL ION SELECTIVE E, P49
  • [5] BERGVELD P, 1988, COMPREHENSIVE ANAL C, V23
  • [6] BUCK RP, 1992, BIOSENSORS CHEM SENS
  • [7] EXTRACELLULAR AND INTRACELLULAR HYDROGEN ION-SELECTIVE MICROELECTRODE BASED ON NEUTRAL CARRIERS WITH EXTENDED PH RESPONSE RANGE IN ACID-MEDIA
    CHAO, P
    AMMANN, D
    OESCH, U
    SIMON, W
    LANG, F
    [J]. PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1988, 411 (02): : 216 - 219
  • [8] CHENG PS, 1980, NATL SCI COUN MONOGR, V8, P313
  • [9] APPLICATION OF AZOLES AS NEUTRAL CARRIERS IN LIQUID MEMBRANE ION-SELECTIVE PH ELECTRODES
    CHOJNACKI, J
    BIERNAT, JF
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1990, 277 (1-2): : 159 - 164
  • [10] NEW NEUTRAL CARRIER-BASED H+ SELECTIVE-MEMBRANE ELECTRODES
    COSOFRET, VV
    NAHIR, TM
    LINDNER, E
    BUCK, RP
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1992, 327 (1-2): : 137 - 146