BIAXIAL STRAIN ANALYSIS OF THE PORCINE AORTIC-VALVE

被引:52
作者
LO, D [1 ]
VESELY, I [1 ]
机构
[1] UNIV WESTERN ONTARIO,JOHN P ROBARTS RES INST,LONDON,ON,CANADA
关键词
D O I
10.1016/0003-4975(95)00249-K
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The function of a bioprosthetic heart valve is determined largely by the material properties of the valve cusps. The mechanics of natural and bioprosthetic valve cusps have been studied extensively using uniaxial tensile testing. This type of testing, however, does not duplicate the natural biaxial loading condition. Whole-valve biaxial testing therefore is preferred. The objective of the present study was to investigate the heterogeneity of the valve cusps by mapping out the regional variability of the biaxial strain versus pressure relationship. Whole porcine aortic valves were mounted horizontally, submerged in physiologic saline solution at 37 degrees C, and pressurized in the range of 0 to 130 mm Hg of pressure. The ventricular side of the cusps were marked with black dots and the three-dimensional position of these dots was recorded together with the aortic pressure. By calculating the distance between the dots in the radial and circumferential directions in different regions, the local strain versus pressure relationship was determined. The results showed that the valve cusp material strained by 23% +/- 0.8% in the radial direction and 10.0% +/-0.5% in the circumferential direction before lock-up. It was also found that while the valve cusp was highly anisotropic in the central region, the basal region was relatively isotropic, and the cusp as a whole was asymmetrical in its distensibility.
引用
收藏
页码:S374 / S378
页数:5
相关论文
共 14 条
[1]   INFLUENCE OF FIXATION CONDITIONS ON THE PERFORMANCE OF GLUTARALDEHYDE-TREATED PORCINE AORTIC VALVES - TOWARDS A MORE SCIENTIFIC BASIS [J].
BROOM, ND ;
THOMSON, FJ .
THORAX, 1979, 34 (02) :166-176
[2]  
Chapra S., 2015, NUMERICAL METHODS EN
[3]  
DAVID H, 1993, ASAIO J, V40, P206
[4]  
FEDERER WT, 1955, EXPT DESIGN, P271
[5]  
FUNG YC, 1981, BIOMECHANICS MECH PR, P22
[6]   THE GLUTARALDEHYDE-STABILIZED PORCINE AORTIC-VALVE XENOGRAFT .1. TENSILE VISCOELASTIC PROPERTIES OF THE FRESH LEAFLET MATERIAL [J].
LEE, JM ;
COURTMAN, DW ;
BOUGHNER, DR .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1984, 18 (01) :61-77
[7]   THE GLUTARALDEHYDE-STABILIZED PORCINE AORTIC-VALVE XENOGRAFT .2. EFFECT OF FIXATION WITH OR WITHOUT PRESSURE ON THE TENSILE VISCOELASTIC PROPERTIES OF THE LEAFLET MATERIAL [J].
LEE, JM ;
BOUGHNER, DR ;
COURTMAN, DW .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1984, 18 (01) :79-98
[8]  
LESSON J, 1994, THESIS U W ONTARIO L, P40
[9]  
MAYNE ASD, 1989, J THORAC CARDIOV SUR, V98, P170
[10]  
MISSILLIS YF, 1978, BIOMAT MED DEV ARTIF, V6, P225