AUTOTUNING OF MULTILOOP CONTROL-SYSTEMS

被引:46
作者
FRIMAN, M [1 ]
WALLER, KV [1 ]
机构
[1] FINLAND SWEDISH UNIV ABO,DEPT CHEM ENGN,PROC CONTROL LAB,SF-20500 TURKU 50,FINLAND
关键词
D O I
10.1021/ie00031a011
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Autotuning by relay feedback is studied with emphasis on multiloop PID control of two-input two-output systems. For the purpose of control design many chemical engineering processes can be modeled by integrator-plus-dead-time or gain-plus-dead-time models. Relay feedback is a convenient method to identify the model parameters, the form of the output response indicating which model is preferable. For a multi-input multi-output process, the off-diagonal elements can be determined in the same experiment as the diagonal elements. The usefulness of the approach is illustrated by a number of systems, including processes with inverse response. Two experimental two-input two-output processes, a mixing tank and a distillation column are used, both with and without decoupling. The approach results in decouplers of simple forms. Autotuning is useful also for tuning the decoupled system.
引用
收藏
页码:1708 / 1717
页数:10
相关论文
共 31 条
[1]  
Astrom K. J., 1990, Proceedings of the 1990 American Control Conference (IEEE Cat. No.90CH2896-9), P1599
[2]  
Astrom K.J., 2013, ADAPTIVE CONTROL
[3]  
Astrom K. J., 1988, AUTOMATIC TUNING PID
[4]  
ASTROM KJ, 1984, AUTOMATICA, V20, P645, DOI 10.1016/0005-1098(84)90014-1
[5]   MONITORING PROCEDURE FOR INTELLIGENT CONTROL - ONLINE IDENTIFICATION OF MAXIMUM CLOSED-LOOP LOG MODULUS [J].
CHIANG, RC ;
YU, CC .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 1993, 32 (01) :90-99
[6]  
CHIANG RC, 1992, IND ENG CHEM RES, V31, P855
[7]  
CHIEN IL, 1990, CHEM ENG PROG OCT, P33
[8]  
FRIMAN M, 1992, THESIS ABO AKADEMI A
[9]  
Haggblom K.E, 1993, P EUR CONTR C, P643
[10]   EXPERIMENTAL COMPARISON OF CONVENTIONAL AND NONLINEAR MODEL-BASED CONTROL OF A MIXING TANK [J].
HAGGBLOM, KE .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 1993, 32 (11) :2653-2661