STEROID ELUTION IMPROVES THE STIMULATION THRESHOLD IN AN ACTIVE-FIXATION ATRIAL PERMANENT PACING LEAD - A RANDOMIZED, CONTROLLED-STUDY

被引:56
作者
CROSSLEY, GH
BRINKER, JA
REYNOLDS, D
SPENCER, W
JOHNSON, WB
HURD, H
TONDER, L
ZMIJEWSKI, M
机构
[1] JOHNS HOPKINS UNIV,BALTIMORE,MD
[2] UNIV OKLAHOMA,OKLAHOMA CITY,OK
[3] BAYLOR COLL MED,HOUSTON,TX 77030
[4] MERCY HOSP,DES MOINES,IA
[5] WASHINGTON UNIV,ST LOUIS,MO
[6] MEDTRONIC INC,MINNEAPOLIS,MN
关键词
PACEMAKERS; ELECTRICAL STIMULATION; TRIALS;
D O I
10.1161/01.CIR.92.10.2935
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Prior work suggests that the addition of a steroid-eluting reservoir to a passive-fixation permanent pace maker lead improves the stimulation threshold; however, no large randomized study has addressed this issue. Over the last several years, there has been an increase in enthusiasm for the use of active-fixation permanent pacemaker leads for various reasons in spite of the generally accepted notion that active-fixation leads have higher stimulation thresholds. Methods and Results This multicenter, randomized, controlled study examined the difference in performance between a standard active-fixation atrial lead (Medtronic model 4058) and a steroid-eluting lead (Medtronic model 4068). Stimulation thresholds were obtained in a four-point strength-duration fashion. Evaluations of sensing and impedance were performed as well. These evaluations were performed at implantation, at weeks 1 through 4, and at weeks 6, 12, 24, and 52. Stimulation thresholds were significantly better in the steroid lead than in the nonsteroid lead at each measurement point from 1 week to 12 months. The mean 1.6-V stimulation threshold at 12 months was 0.19+/-0.2 ms in the steroid lead and 0.41+/-0.30 ms in the control lead. No acute peaking was observed with the steroid lead, whereas significant peaking was observed with the control lead. There was no difference in long-term sensing or impedance. Conclusions Inclusion of a steroid-eluting reservoir in an active-fixation permanent pacing lead improved stimulation thresholds in both the subacute and chronic periods and therefore should extend pulse-generator longevity.
引用
收藏
页码:2935 / 2939
页数:5
相关论文
共 17 条
[1]   3-YEAR CLINICAL-EXPERIENCE WITH A NEW ENDOCARDIAL SCREW-IN LEAD WITH INTRODUCTION PROTECTION FOR USE IN THE ATRIUM AND VENTRICLE [J].
BISPING, HJ ;
KREUZER, J ;
BIRKENHEIER, H .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1980, 3 (04) :424-435
[2]  
DUNNETT CW, 1987, JASA, V417, P162
[3]   ACTIVE FIXATION OF ENDOCARDIAL PACING LEADS - THE PREFERRED METHOD OF PEDIATRIC PACING [J].
FRIEDMAN, RA ;
MOAK, JP ;
GARSON, A .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1991, 14 (08) :1213-1216
[4]   A RANDOMIZED COMPARISON OF A BIPOLAR STEROID-ELUTING ELECTRODE AND A BIPOLAR MICROPOROUS PLATINUM-ELECTRODE - IMPLICATIONS FOR LONG-TERM PROGRAMMING [J].
GILLIS, AM ;
ROTHSCHILD, JM ;
HILLIER, K ;
FUDGE, W ;
KIESER, TM ;
MAITLAND, A .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1993, 16 (05) :964-970
[5]   THE RIGHT ATRIAL FREE WALL - AN ALTERNATIVE PACING SITE [J].
JAMIDAR, H ;
GOLI, V ;
REYNOLDS, DW .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1993, 16 (05) :959-963
[6]   STEROID-ELUTING EPICARDIAL PACING LEADS IN PEDIATRIC-PATIENTS - ENCOURAGING EARLY RESULTS [J].
JOHNS, JA ;
FISH, FA ;
BURGER, JD ;
HAMMON, JW .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 20 (02) :395-401
[7]   ACTIVE FIXATION ATRIAL LEADS - RANDOMIZED COMPARISON OF 2 LEAD DESIGNS [J].
KAY, GN ;
ANDERSON, K ;
EPSTEIN, AE ;
PLUMB, VJ .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1989, 12 (08) :1355-1361
[8]   ATRIAL PACEMAKER LEADS COMPARED [J].
MASTERSON, MM ;
MALONEY, JD ;
TUZCU, EM ;
WILKOFF, BL ;
EMRE, A ;
VANERIO, G ;
SIMMONS, TW ;
MORANT, VA ;
CASTLE, LW .
CLEVELAND CLINIC JOURNAL OF MEDICINE, 1990, 57 (05) :433-436
[9]   THE POROUS TITANIUM STEROID ELUTING ELECTRODE - A DOUBLE-BLIND STUDY ASSESSING THE STIMULATION THRESHOLD EFFECTS OF STEROID [J].
MOND, H ;
STOKES, K ;
HELLAND, J ;
GRIGG, L ;
KERTES, P ;
PATE, B ;
HUNT, D .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (02) :214-219
[10]   IMPLANTATION OF A DUAL CHAMBER PACEMAKER IN A PATIENT WITH PERSISTENT LEFT SUPERIOR VENA-CAVA [J].
ROBERTS, DH ;
BELLAMY, CM ;
RAMSDALE, DR .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 1992, 36 (02) :242-243