AN IMPROVED METHOD FOR FAULT LOCATION OF CHEMICAL-PLANTS

被引:13
作者
QIAN, DQ
机构
[1] Automatic Control Department, Shanghai Jiao Tong University, Shanghai
关键词
D O I
10.1016/0098-1354(90)87004-9
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
This paper proposes an improved method based on Kokawa's approach (Kokawa et al., 1983, Automatica 19, 729) for fault location in large-scale chemical plants. In this method, a frame system is used to describe the failure propagation network in detail. Human experience on failure propagation is represented in a fuzzy sense. The signed node and branch is introduced for representing abnormal symptoms of failure propagation. A new fault location procedure is given. As an illustrative example, a pump system in a liquefied petroleum gas plant has been taken up to show the usefulness of the proposed method. © 1990.
引用
收藏
页码:41 / 48
页数:8
相关论文
共 8 条
[1]   PROCESS FAULT-DETECTION BASED ON MODELING AND ESTIMATION METHODS - A SURVEY [J].
ISERMANN, R .
AUTOMATICA, 1984, 20 (04) :387-404
[2]   FAULT LOCATION USING DIGRAPH AND INVERSE DIRECTION SEARCH WITH APPLICATION [J].
KOKAWA, M ;
MIYAZAKI, S ;
SHINGAI, S .
AUTOMATICA, 1983, 19 (06) :729-735
[3]   A RULE-BASED APPROACH TO FAULT-DIAGNOSIS USING THE SIGNED DIRECTED GRAPH [J].
KRAMER, MA ;
PALOWITCH, BL .
AICHE JOURNAL, 1987, 33 (07) :1067-1078
[4]  
LAPP SA, 1977, IEEE T RELIAB, V26, P62
[5]   EVIDENCE COMBINATION IN EXPERT SYSTEMS [J].
LESMO, L ;
SAITTA, L ;
TORASSO, P .
INTERNATIONAL JOURNAL OF MAN-MACHINE STUDIES, 1985, 22 (03) :307-326
[6]  
TRI M, 1979, COMPUT CHEM ENG, V3, P489
[7]  
VESELKY WE, 1970, PREP KITT COMPUTER C
[8]  
ZIMMERMANN HJ, 1985, FUZZY SET THEORY ITS, P51