THE RELATIONSHIP OF BLOOD-FLOW VELOCITY FLUCTUATIONS TO INTRACRANIAL-PRESSURE B-WAVES

被引:129
作者
NEWELL, DW
AASLID, R
STOOSS, R
REULEN, HJ
机构
[1] UNIV BERN,DEPT NEUROSURG,CH-3000 BERN,SWITZERLAND
[2] UNIV WASHINGTON,DEPT NEUROL SURG,SEATTLE,WA 98195
关键词
INTRACRANIAL PRESSURE; B-WAVE; TRANSCRANIAL DOPPLER ULTRASOUND; INTRACRANIAL PRESSURE MONITORING; HEAD INJURY;
D O I
10.3171/jns.1992.76.3.0415
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Intracranial pressure (ICP) and continuous transcranial Doppler ultrasound signals were monitored in 20 head-injured patients and simultaneous synchronous fluctuations of middle cerebral artery (MCA) velocity and B waves of the ICP were observed. Continuous simultaneous monitoring of MCA velocity, ICP, arterial blood pressure, and expired CO2 revealed that both velocity waves and B waves occurred despite a constant CO2 concentration in ventilated patients and were usually not accompanied by fluctuations in the arterial blood pressure. Additional recordings from the extracranial carotid artery during the ICP B waves revealed similar synchronous fluctuations in the velocity of this artery, strongly supporting the hypothesis that blood flow fluctuations produce the velocity waves. The ratio between ICP wave amplitude and velocity wave amplitude was highly correlated to the ICP (r = 0.8 1, p < 0.001). Velocity waves of similar characteristics and frequency, but usually of shorter duration, were observed in seven of 10 normal subjects in whom MCA velocity was recorded for 1 hour. The findings in this report strongly suggest that B waves in the ICP are a secondary effect of vasomotor waves, producing cerebral blood flow fluctuations that become amplified in the ICP tracing, in states of reduced intracranial compliance.
引用
收藏
页码:415 / 421
页数:7
相关论文
共 19 条
[1]   CEREBRAL AUTO-REGULATION DYNAMICS IN HUMANS [J].
AASLID, R ;
LINDEGAARD, KF ;
SORTEBERG, W ;
NORNES, H .
STROKE, 1989, 20 (01) :45-52
[2]   NON-INVASIVE TRANSCRANIAL DOPPLER ULTRASOUND RECORDING OF FLOW VELOCITY IN BASAL CEREBRAL-ARTERIES [J].
AASLID, R ;
MARKWALDER, TM ;
NORNES, H .
JOURNAL OF NEUROSURGERY, 1982, 57 (06) :769-774
[3]  
AASLID R, 1991, STROKE, V22, P148
[4]   INTRACRANIAL-PRESSURE OSCILLATIONS (B-WAVES) CAUSED BY OSCILLATIONS IN CEREBROVASCULAR VOLUME [J].
AUER, LM ;
SAYAMA, I .
ACTA NEUROCHIRURGICA, 1983, 68 (1-2) :93-100
[5]   TRANSCRANIAL DOPPLER MEASUREMENT OF MIDDLE CEREBRAL-ARTERY BLOOD-FLOW VELOCITY - A VALIDATION-STUDY [J].
BISHOP, CCR ;
POWELL, S ;
RUTT, D ;
BROWSE, NL .
STROKE, 1986, 17 (05) :913-915
[6]   CEREBROSPINAL-FLUID CONDUCTANCE AND COMPLIANCE OF THE CRANIOSPINAL SPACE IN NORMAL-PRESSURE HYDROCEPHALUS - COMPARISON BETWEEN 2 METHODS FOR MEASURING CONDUCTANCE TO OUTFLOW [J].
BORGESEN, SE ;
GJERRIS, F ;
SORENSEN, SC .
JOURNAL OF NEUROSURGERY, 1979, 51 (04) :521-525
[7]  
DIRNAGL U, 1989, INTRACRANIAL PRESSUR, V7, P213
[8]   THE FREQUENCY-DEPENDENT BEHAVIOR OF CEREBRAL AUTOREGULATION [J].
GILLER, CA .
NEUROSURGERY, 1990, 27 (03) :362-368
[9]  
HASHIMOTO M, 1989, INTRACRANIAL PRESSUR, V7, P217
[10]  
HIGASHI S, 1989, INTRACRANIAL PRESSUR, V7, P220