摘要
Analysis of radiation doses in interventional radiological procedures that can lead to deterministic radiation effects such as erythema and epilation would assist physicians in planning patient care after exposure and in reducing doses. Photographic films used to measure skin exposure in the past are too sensitive for the high doses involved in interventional procedures. Seventeen different types of films, many of which are generally available in hospitals, were surveyed to see if any would meet the demands of interventional radiology. Sensitometric curves obtained demonstrate that most films are inappropriate for high dose procedures. Using Kodak Fine Grain Positive and Dupont duplicating films and automatic processing, doses as high as 2.8 Gy could be measured with reasonable accuracy. Similar results can be obtained by manually processing Kodak XV-2 verification film at room temperature.
引用
收藏
页码:595 / 599
页数:5
相关论文
共 11 条
[1]  
Attix FH., 1986, INTRO RADIOLOGICAL P, P358
[2]  
BECKER K, 1966, PHOTOGRAPHIC FILM DO
[3]   A PHOTOGRAPHIC METHOD OF MEASURING FLUOROSCOPIC DOSE TO THE PATIENT [J].
BLATZ, H ;
EPP, ER .
RADIOLOGY, 1961, 76 (01) :120-121
[4]   RECIPROCITY LAW FOR X-RAYS .1. VALIDITY FOR HIGH-INTENSITY EXPOSURES IN THE NEGATIVE REGION [J].
EHRLICH, M ;
MCLAUGHLIN, WL .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1956, 46 (10) :797-800
[5]   RADIOTHERAPY VERIFICATION FILM FOR ESTIMATING CUMULATIVE ENTRANCE SKIN EXPOSURE FOR FLUOROSCOPIC EXAMINATIONS [J].
GEISE, RA ;
ANSEL, HJ .
HEALTH PHYSICS, 1990, 59 (03) :295-298
[6]  
GRAY JE, 1977, HEW FDA778018 PUBL
[7]   A METHOD FOR ESTIMATING THE AVERAGE BONE-MARROW DOSE FROM SOME FLUOROSCOPIC EXAMINATIONS [J].
LIUZZI, A ;
BLATZ, H ;
EISENBUD, M .
RADIOLOGY, 1964, 82 (01) :99-105
[8]  
MEES CEK, 1971, THEORY PHOTOGRAPHIC
[9]   EXPOSURE PATTERN, SURFACE, BONE-MARROW INTEGRAL AND GONADAL DOSE FROM FLUOROSCOPY [J].
TAKESHITA, K ;
SAWADA, S ;
ANTOKU, S .
BRITISH JOURNAL OF RADIOLOGY, 1972, 45 (529) :53-+
[10]   FILM DOSIMETRY OF MEGAVOLTAGE PHOTON BEAMS - A PRACTICAL METHOD OF ISODENSITY-TO-ISODOSE CURVE CONVERSION [J].
WILLIAMSON, JF ;
KHAN, FM ;
SHARMA, SC .
MEDICAL PHYSICS, 1981, 8 (01) :94-98