LOW-INTENSITY ANTICOAGULATION IN MECHANICAL CARDIAC PROSTHETIC VALVES

被引:32
作者
WILSON, DB
DUNN, MI
HASSANEIN, K
机构
[1] UNIV KANSAS,MED CTR,DEPT INTERNAL MED,DIV CARDIOVASC DIS,KANSAS CITY,KS 66103
[2] UNIV KANSAS,MED CTR,DEPT BIOMETRY,KANSAS CITY,KS 66103
关键词
D O I
10.1378/chest.100.6.1553
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Retrospectively, we reviewed the charts of 101 patients at the University of Kansas Medical Center who received low-intensity anticoagulation for mechanical prosthetic valves implanted over a 17-yr period. The mean duration of follow-up was 4.6 yr, and the total duration of follow-up was 466.5 patient-yr. The patients' records were evaluated for evidence of hemorrhagic or thromboembolic complications. A prothrombin time ratio of 1.3 to 1.5 times control was considered to be low-intensity anticoagulation. There were three thromboembolic events or 2.9/100 patient-yr of follow-up at a prothrombin time ratio of less than 1.3, four thromboembolic events or 2.5/100 patient-yr of follow-up at 1.3 to 1.5 times control, four thromboembolic events or 2.2/100 patient-yr of follow-up at 1.6 to 2.0 times control, and no thromboembolic events at prothrombin time ratios greater than 2.0 times control. Hemorrhagic events occurred in three patients at a prothrombin time ratio of less than 1.3 times control or 2.8/100 patient-yr of follow-up, in six patients at 1.3 to 1.5 times control or 3.8/100 patient-yr of follow-up, in ten patients at 1.6 to 2.0 times control or 5.5/100 patient-yr of follow-up, and in two patients at 2.1 to 2.5 times control or 12.2/100 patient-yr of follow-up. The rate of hemorrhagic events at 2.5 times control was 470/100 patient-yr of follow-up. While not providing definitive proof, we believe that our retrospective study provides supportive evidence for the use of low-intensity anticoagulation in patients with mechanical cardiac prostheses.
引用
收藏
页码:1553 / 1557
页数:5
相关论文
共 6 条
[1]   THERAPEUTIC RANGE FOR ORAL ANTICOAGULANT-THERAPY [J].
HIRSH, J ;
DEYKIN, D ;
POLLER, L .
CHEST, 1986, 89 (02) :S11-S15
[2]   DIFFERENT INTENSITIES OF ORAL ANTICOAGULANT-THERAPY IN THE TREATMENT OF PROXIMAL-VEIN THROMBOSIS [J].
HULL, R ;
HIRSH, J ;
JAY, R ;
CARTER, C ;
ENGLAND, C ;
GENT, M ;
TURPIE, AGG ;
MCLOUGHLIN, D ;
DODD, P ;
THOMAS, M ;
RASKOB, G ;
OCKELFORD, P .
NEW ENGLAND JOURNAL OF MEDICINE, 1982, 307 (27) :1676-1681
[3]  
MCGOON DC, 1984, J THORAC CARDIOV SUR, V88, P782
[4]   TRIAL OF DIFFERENT INTENSITIES OF ANTICOAGULATION IN PATIENTS WITH PROSTHETIC HEART-VALVES [J].
SAOUR, JN ;
SIECK, JO ;
MAMO, LAR ;
GALLUS, AS .
NEW ENGLAND JOURNAL OF MEDICINE, 1990, 322 (07) :428-432
[5]   ANTITHROMBOTIC THERAPY IN MECHANICAL AND BIOLOGICAL PROSTHETIC HEART-VALVES AND SAPHENOUS-VEIN BYPASS GRAFTS [J].
STEIN, PD ;
KANTROWITZ, A .
CHEST, 1989, 95 (02) :S107-S117
[6]  
TURPIE AGG, 1988, LANCET, V1, P1242