A HYDROLYSIS METHOD USING MICROWAVES - DETERMINATION OF N-ACETYL- AND N-GLYCOLYLNEURAMINIC ACIDS IN BIOLOGICAL-SYSTEMS BY FLUOROMETRIC HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY

被引:18
作者
LAGANA, A [1 ]
MARINO, A [1 ]
FAGO, G [1 ]
MARTINEZ, BP [1 ]
机构
[1] HOSP CENT SUR PETR MEXICANOS,MEXICO CITY,DF,MEXICO
关键词
D O I
10.1006/abio.1993.1585
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple, rapid, and extremely sensitive method for determining N-acetyl- and N-glycolylneuraminic acids in serum and in submandibular, sublingual, and parotid glands using high-performance liquid chromatography with a fluorometric detector is described. The neuraminic acids contained in the samples are released in the presence of 2 M CH3COOH by means of microwave hydrolysis (only 10 min required) and are subsequently converted using 1,2-diamino-4,5-methylenedioxybenzene, a fluorogenic reagent for α-ketoacids, into highly fluorescent derivatives. In order to optimize the release of sialic acids and to minimize the effect of destruction, the following analytical variables were investigated: temperature, time, and concentration of the acid. Within 12 min after derivatization, the compounds were separated on a reversed-phase column by means of isocratic elution using a mobile phase of water (pH 3 with H3PO4)-methanol-acetonitrile (86:6:8, v/v). Fluorescence detection was performed at an excitation wavelength of 373 nm and an emission wavelength of 448 nm. © 1993 Academic Press, Inc.
引用
收藏
页码:266 / 272
页数:7
相关论文
共 20 条
[1]  
COLLI A, 1989, CANCER, V63, P912, DOI 10.1002/1097-0142(19890301)63:5<912::AID-CNCR2820630521>3.0.CO
[2]  
2-W
[3]   HIGHLY SENSITIVE DETERMINATION OF N-ACETYL-NEURAMINIC AND N-GLYCOLYLNEURAMINIC ACIDS IN HUMAN-SERUM AND URINE AND RAT SERUM BY REVERSED-PHASE LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION [J].
HARA, S ;
YAMAGUCHI, M ;
TAKEMORI, Y ;
NAKAMURA, M ;
OHKURA, Y .
JOURNAL OF CHROMATOGRAPHY, 1986, 377 :111-119
[4]   DETERMINATION OF MONO-O-ACETYLATED N-ACETYLNEURAMINIC ACIDS IN HUMAN AND RAT SERA BY FLUOROMETRIC HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
HARA, S ;
YAMAGUCHI, M ;
TAKEMORI, Y ;
FURUHATA, K ;
OGURA, H ;
NAKAMURA, M .
ANALYTICAL BIOCHEMISTRY, 1989, 179 (01) :162-166
[5]   FLUOROMETRIC HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF N-ACETYLNEURAMINIC AND N-GLYCOLYLNEURAMINIC ACIDS AND ITS APPLICATION TO THEIR MICRODETERMINATION IN HUMAN AND ANIMAL SERA, GLYCOPROTEINS, AND GLYCOLIPIDS [J].
HARA, S ;
TAKEMORI, Y ;
YAMAGUCHI, M ;
NAKAMURA, M ;
OHKURA, Y .
ANALYTICAL BIOCHEMISTRY, 1987, 164 (01) :138-145
[6]  
HARVEY HA, 1981, CANCER, V47, P324, DOI 10.1002/1097-0142(19810115)47:2<324::AID-CNCR2820470219>3.0.CO
[7]  
2-L
[8]  
Jassie L.B., 1988, INTRO MICROWAVE SAMP, P1
[9]   DETERMINATION OF N-ACETYLNEURAMINIC AND N-GLYCOLYLNEURAMINIC ACIDS IN GLYCOCONJUGATES BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ULTRAVIOLET DETECTION [J].
KARAMANOS, NK ;
WIKSTROM, B ;
ANTONOPOULOS, CA ;
HJERPE, A .
JOURNAL OF CHROMATOGRAPHY, 1990, 503 (02) :421-429
[10]   SENSITIVE AUTOANALYTICAL METHOD FOR SIALIC ACIDS [J].
KRANTZ, MJ ;
LEE, YC .
ANALYTICAL BIOCHEMISTRY, 1975, 63 (02) :464-469