CONSEQUENCES OF MISFILLING CONTEMPORARY VAPORIZERS WITH DESFLURANE

被引:17
作者
ANDREWS, JJ
JOHNSTON, RV
KRAMER, GC
机构
[1] Department of Anesthesiology, The University of Texas Medical Branch, Galveston, Texas
来源
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE | 1993年 / 40卷 / 01期
关键词
ANESTHETICS; GASES; DESFLURANE; EQUIPMENT; VAPORIZERS;
D O I
10.1007/BF03009323
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Desflurane is a volatile anaesthetic that combines low blood gas solubility (blood/gas partition coefficient = 0.42 at 37-degree-C), moderate potency (MAC = 6-7%), and high volatility (vapour pressure = 681 mmHg at 20-degrees-C, boiling point = 23.5-degrees-C). The volatility and potency of desflurane prevent its safe use in vaporizers of traditional design. We present a mathematical model which demonstrates the potential for desflurane overdose if contemporary vaporizers are misfilled with desflurane. The most hazardous filling error occurs if an enflurane vaporizer is misfilled with desflurane. The calculated desflurane output of a misfilled enflurane vaporizer at a dial setting of 1% and a temperature of 22-degrees-C is 57.8%, or 9.6 MAC. For misfilled enflurane, isoflurane, and halothane vaporizers at dial settings equivalent to one MAC at 22-degrees-C, the calculated desflurane output is 14.0, 10.2, and 78 MAC, respectively. We conclude that the safe delivery of desflurane will require engineering safeguards, additional monitoring, and education of the anesthesia community.
引用
收藏
页码:71 / 76
页数:6
相关论文
共 13 条
  • [1] DORSCH JA, 1975, UNDERRSTANDING ANEST
  • [2] DORSCH JA, 1984, UNDERSTANDING ANESTH
  • [3] EGER EI, 1987, ANESTH ANALG, V66, P971
  • [4] FAILURE OF KEYED AGENT-SPECIFIC FILLING DEVICES
    GEORGE, TM
    [J]. ANESTHESIOLOGY, 1984, 61 (02) : 228 - 229
  • [5] BIOTRANSFORMATION AND HEPATORENAL FUNCTION IN VOLUNTEERS AFTER EXPOSURE TO DESFLURANE (I-653)
    JONES, RM
    KOBLIN, DD
    CASHMAN, JN
    EGER, EI
    JOHNSON, BH
    DAMASK, MC
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 1990, 64 (04) : 482 - 487
  • [6] DESFLURANE AND SEVOFLURANE - INHALATION ANESTHETICS FOR THIS DECADE
    JONES, RM
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 1990, 65 (04) : 527 - 536
  • [7] KARIS JH, 1982, ANESTH ANALG, V61, P53
  • [8] CLINICAL CHARACTERISTICS OF DESFLURANE IN SURGICAL PATIENTS - MINIMUM ALVEOLAR CONCENTRATION
    RAMPIL, IJ
    LOCKHART, SH
    ZWASS, MS
    PETERSON, N
    YASUDA, N
    EGER, EI
    WEISKOPF, RB
    DAMASK, MC
    [J]. ANESTHESIOLOGY, 1991, 74 (03) : 429 - 433
  • [9] RENDELLBAKER L, 1982, INT ANESTHESIOL CLIN, V20, P45
  • [10] FAILURE OF THE AGENT-SPECIFIC FILLING DEVICE
    RIEGLE, EV
    DESERTSPRING, D
    [J]. ANESTHESIOLOGY, 1990, 73 (02) : 353 - 354