ANODIC-STRIPPING VOLTAMMETRY OF LEAD, CADMIUM AND ZINC IN THE PRESENCE OF COPPER WITH AN ION-EXCHANGE COLUMN

被引:8
作者
DALANGIN, RR
GUNASINGHAM, H
机构
关键词
ANODIC STRIPPING VOLTAMMETRY; ION-EXCHANGE COLUMN; LEAD; COPPER; ZINC AND CADMIUM; FLOW INJECTION ANALYSIS; WALL-JET DETECTOR;
D O I
10.1039/an9941902187
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The determination of lead, cadmium and zinc by anodic stripping voltammetry is made difficult by the presence of large amounts of copper. For lead, ordinarily, 0.10 mg l(-1) of lead is totally suppressed by the presence of 100 mg l(-1) of copper (molar ratio of copper to lead = 3261.5) owing to the very high background currents brought about by undissolved copper atoms. For zinc and cadmium, intermetallic compound formation occurs, which affects the stripping peak currents of both metals. In this work, on-line ion-exchange separation was used prior to differential-pulse anodic stripping voltammetry (DPASV) for the determination of lead, zinc and cadmium in the presence of excess of copper. A commercially available resin, Dowex XFS 43084, allowed suppression of the copper stripping peak. An additional use of the ion-exchange column is to extend the useful range of DPASV for the determination of topper to the millimolar range.
引用
收藏
页码:2187 / 2191
页数:5
相关论文
共 35 条
[1]   DETERMINATION OF ZINC, CADMIUM, LEAD AND COPPER IN A SINGLE SEA-WATER SAMPLE BY DIFFERENTIAL PULSE ANODIC-STRIPPING VOLTAMMETRY [J].
ABDULLAH, MI ;
BERG, BR ;
KLIMEK, R .
ANALYTICA CHIMICA ACTA, 1976, 84 (02) :307-317
[2]   DETERMINATION OF SELENIUM(IV) BY ANODIC-STRIPPING VOLTAMMETRY IN FLOW SYSTEM WITH ION-EXCHANGE SEPARATION [J].
ANDREWS, RW ;
JOHNSON, DC .
ANALYTICAL CHEMISTRY, 1976, 48 (07) :1056-1060
[3]  
[Anonymous], 1985, STRIPPING ANAL PRINC
[4]   ANODIC-STRIPPING VOLTAMMETRY OF SELENIUM IN THE PRESENCE OF COPPER-ION [J].
AYDIN, H ;
SOMER, G .
ANALYTICAL SCIENCES, 1989, 5 (01) :89-93
[5]   DIRECT SIMULTANEOUS DETERMINATION OF TRACE AMOUNTS (PPB) OF ZINC(II), CADMIUM(II), LEAD(II), AND COPPER(II) IN GROUND AND SPRING WATERS USING ANODIC-STRIPPING VOLTAMMETRY - ANALYTICAL METHOD [J].
BENBASSAT, AHI ;
BLINDERMANN, JM ;
SALOMON, A .
ANALYTICAL CHEMISTRY, 1975, 47 (03) :534-537
[6]   DETERMINATION OF LABILE AND STRONGLY BOUND METALS IN LAKE WATER [J].
CHAU, YK ;
LUMSHUEC.K .
WATER RESEARCH, 1974, 8 (06) :383-388
[7]   ELIMINATION OF COPPER-ZINC INTERMETALLIC INTERFERENCES IN ANODIC-STRIPPING VOLTAMMETRY [J].
COPELAND, TR ;
OSTERYOU.RA ;
SKOGERBO.RK .
ANALYTICAL CHEMISTRY, 1974, 46 (14) :2093-2097
[8]   PULSED ANODIC-STRIPPING VOLTAMMETRY OF ZINC, CADMIUM AND LEAD WITH A MERCURY-COATED WAX-IMPREGNATED GRAPHITE ELECTRODE [J].
CROSMUN, ST ;
DEAN, JA ;
STOKELY, R .
ANALYTICA CHIMICA ACTA, 1975, 75 (02) :421-430
[9]   THIN-LAYER DIFFERENTIAL PULSE VOLTAMMETRY [J].
DEANGELIS, TP ;
BOND, RE ;
BROOKS, EE ;
HEINEMAN, WR .
ANALYTICAL CHEMISTRY, 1977, 49 (12) :1792-1797
[10]   DETERMINATION OF CADMIUM, LEAD, COPPER AND ZINC IN GROUND-WATER, ESTUARINE WATER, SEWAGE AND SEWAGE EFFLUENT BY ANODIC-STRIPPING VOLTAMMETRY [J].
GARDINER, J ;
STIFF, MJ .