ANALYTICAL APPLICATION OF MICROCALORIMETRY - A STOP-FLOW MIXING DEVICE
被引:8
作者
:
PENNINGTON, SN
论文数:
0
引用数:
0
h-index:
0
机构:
Biochemistry Section, Cancer Research Center, Columbia
PENNINGTON, SN
BROWN, HD
论文数:
0
引用数:
0
h-index:
0
机构:
Biochemistry Section, Cancer Research Center, Columbia
BROWN, HD
BERGER, RL
论文数:
0
引用数:
0
h-index:
0
机构:
Biochemistry Section, Cancer Research Center, Columbia
BERGER, RL
EVANS, WJ
论文数:
0
引用数:
0
h-index:
0
机构:
Biochemistry Section, Cancer Research Center, Columbia
EVANS, WJ
机构
:
[1]
Biochemistry Section, Cancer Research Center, Columbia
[2]
Laboratory for Instrumental Development, National Heart Institute, Bethesda
[3]
Southern Regional Research Laboratory, Department of Agriculture, New Orleans, LA
来源
:
ANALYTICAL BIOCHEMISTRY
|
1969年
/ 32卷
/ 02期
关键词
:
D O I
:
10.1016/0003-2697(69)90082-7
中图分类号
:
Q5 [生物化学];
学科分类号
:
071010 ;
081704 ;
摘要
:
A stopped-flow (stop-start) mixing device for use in connection with a bench-top microcalorimeter has been designed and constructed. The device employs a ball mixer for rapid combination of solutions pre-equilibrated in spirals of tantalum tubing. Following the mixing procedure, the resultant heat is measured by pumping the mixed solution into Teflon coils situated within the sensing volume of a microcalorimeter. The sensitivity of the flow mixer is comparable to other types of mixers employed in the same instrument and allows serial analyses once equilibrium has been obtained. The sealed nature of the flow cells allows reactions that are sensitive to their environment to be carried out without resorting to inert atmospheres. © 1969.
引用
收藏
页码:251 / +
页数:1
相关论文
共 7 条
[1]
DIFFERENTIAL MICROCALORIMETER FOR BIOCHEMICAL REACTION STUDIES
BERGER, RL
论文数:
0
引用数:
0
h-index:
0
BERGER, RL
CHICK, YBF
论文数:
0
引用数:
0
h-index:
0
CHICK, YBF
DAVIDS, N
论文数:
0
引用数:
0
h-index:
0
DAVIDS, N
[J].
REVIEW OF SCIENTIFIC INSTRUMENTS,
1968,
39
(03)
: 362
-
&
[2]
BERNHARD SA, 1956, J BIOL CHEM, V218, P961
[3]
BROWN HD, 1968, 68C I EL EL ENGRS PU
[4]
MONK P, IN PRESS
[5]
HEATS OF HYDROLYSIS OF ASPIRIN THIOASPIRIN + THEIR RHO-ANALOGUES
NELANDER, L
论文数:
0
引用数:
0
h-index:
0
NELANDER, L
[J].
ACTA CHEMICA SCANDINAVICA,
1964,
18
(04):
: 973
-
&
[6]
DETERMINATION OF VERY SMALL AMOUNTS OF HYDROGEN PEROXIDE
PERSCHKE, H
论文数:
0
引用数:
0
h-index:
0
PERSCHKE, H
BRODA, E
论文数:
0
引用数:
0
h-index:
0
BRODA, E
[J].
NATURE,
1961,
190
(477)
: 257
-
&
[7]
PRECISION FLOW-MICROCALORIMETER
STOESSER, PR
论文数:
0
引用数:
0
h-index:
0
STOESSER, PR
GILL, SJ
论文数:
0
引用数:
0
h-index:
0
GILL, SJ
[J].
REVIEW OF SCIENTIFIC INSTRUMENTS,
1967,
38
(03)
: 422
-
&
←
1
→
共 7 条
[1]
DIFFERENTIAL MICROCALORIMETER FOR BIOCHEMICAL REACTION STUDIES
BERGER, RL
论文数:
0
引用数:
0
h-index:
0
BERGER, RL
CHICK, YBF
论文数:
0
引用数:
0
h-index:
0
CHICK, YBF
DAVIDS, N
论文数:
0
引用数:
0
h-index:
0
DAVIDS, N
[J].
REVIEW OF SCIENTIFIC INSTRUMENTS,
1968,
39
(03)
: 362
-
&
[2]
BERNHARD SA, 1956, J BIOL CHEM, V218, P961
[3]
BROWN HD, 1968, 68C I EL EL ENGRS PU
[4]
MONK P, IN PRESS
[5]
HEATS OF HYDROLYSIS OF ASPIRIN THIOASPIRIN + THEIR RHO-ANALOGUES
NELANDER, L
论文数:
0
引用数:
0
h-index:
0
NELANDER, L
[J].
ACTA CHEMICA SCANDINAVICA,
1964,
18
(04):
: 973
-
&
[6]
DETERMINATION OF VERY SMALL AMOUNTS OF HYDROGEN PEROXIDE
PERSCHKE, H
论文数:
0
引用数:
0
h-index:
0
PERSCHKE, H
BRODA, E
论文数:
0
引用数:
0
h-index:
0
BRODA, E
[J].
NATURE,
1961,
190
(477)
: 257
-
&
[7]
PRECISION FLOW-MICROCALORIMETER
STOESSER, PR
论文数:
0
引用数:
0
h-index:
0
STOESSER, PR
GILL, SJ
论文数:
0
引用数:
0
h-index:
0
GILL, SJ
[J].
REVIEW OF SCIENTIFIC INSTRUMENTS,
1967,
38
(03)
: 422
-
&
←
1
→