INCREASED LIGHT-SCATTERING RESOLUTION FACILITATES MULTIDIMENSIONAL FLOW CYTOMETRIC ANALYSIS

被引:60
作者
TERSTAPPEN, LWMM
MICKAELS, RA
DOST, R
LOKEN, MR
机构
[1] Becton Dickinson Immunocytometry Systems, San Jose, California
来源
CYTOMETRY | 1990年 / 11卷 / 04期
关键词
hematology; Immunofluorescence; leukocyte differentials;
D O I
10.1002/cyto.990110409
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Multidimensional flow cytometry identifies cell populations as clusters in a space created by the analysis of multiple parameters simultaneously. Optimal use of this multidimensional space requires each of the individual parameters to provide additional information for cell population discrimination as well as maximum utilization of the dynamic range available for each parameter. In this study we improve the visualization of the information present in light scattering signals from leukocytes to facilitate multidimensional flow cytometric analysis. Optimization of cell preparation techniques are essential to obtain high resolution light scattering signals that give complete separation of the granulocytes, monocytes, and granular and nongranular lymphocytes. The angle at which the forward scattered light was collected was modified to enhance the separation between leukocyte populations. Although orthogonal light scattering signals separate granular and nongranular lymphocytes, the resolution and dynamic range could not be displayed using linear or logarithmic functions. By applying a polynomial function to the orthogonal light scattering signals, all leukocyte populations could be displayed while maintaining high resolution. The combination of high resolution light scattering with a nonlinear display resulted in an equally spaced distribution of the cell populations distinguished by correlating forward and orthogonal light scattering signals. Using this approach, peripheral blood neutrophils, eosinophils, basophils, monocytes, and granular and nongranular lymphocytes were shown to occupy distinct locations in the correlation of orthogonal and forward light scattering. Surprisingly,the basophilic granulocytes were located close to granular lymphocytes and monocytes rather than near neutrophils and eosinophils. Copyright © 1990 Wiley‐Liss, Inc.
引用
收藏
页码:506 / 512
页数:7
相关论文
共 20 条
[1]   LIGHT-SCATTERING FROM COATED SPHERES - MODEL FOR BIOLOGICAL CELLS [J].
BRUNSTING, A ;
MULLANEY, PF .
APPLIED OPTICS, 1972, 11 (03) :675-+
[2]   LIGHT-SCATTERING POLARIZATION MEASUREMENTS AS A NEW PARAMETER IN FLOW-CYTOMETRY [J].
DEGROOTH, BG ;
TERSTAPPEN, LWMM ;
PUPPELS, GJ ;
GREVE, J .
CYTOMETRY, 1987, 8 (06) :539-544
[3]  
LOKEN MR, 1987, BLOOD, V69, P255
[4]   FLOW CYTOMETRIC ANALYSIS OF NORMAL B-LYMPHOID DEVELOPMENT [J].
LOKEN, MR ;
SHAH, VO ;
HOLLANDER, Z ;
CIVIN, CI .
PATHOLOGY AND IMMUNOPATHOLOGY RESEARCH, 1988, 7 (05) :357-+
[5]  
LOKEN MR, 1987, BLOOD, V70, P1316
[6]  
MIROLI AA, 1986, J IMMUNOL METHODS, V97, P185
[7]  
SALZMAN GC, 1975, ACTA CYTOL, V19, P374
[8]  
SALZMAN GC, 1975, CLIN CHEM, V21, P1297
[9]  
TERSTAPPEN LWM, 1990, IN PRESS J LEUK BIOL
[10]  
TERSTAPPEN LWM, IN PRESS ANAL CELL P