A COMPARISON OF TECHNIQUES FOR STEREOTAXIC RADIOTHERAPY BY LINEAR-ACCELERATOR BASED ON 3-DIMENSIONAL DOSE DISTRIBUTIONS

被引:39
作者
GRAHAM, JD
NAHUM, AE
BRADA, M
机构
[1] ROYAL MARSDEN HOSP,ACAD UNIT RADIOTHERAPY & ONCOL,DOWNS RD,SUTTON SM2 5PT,SURREY,ENGLAND
[2] INST CANC RES,JOINT DEPT PHYS,SUTTON SM2 5PX,SURREY,ENGLAND
[3] INST CANC RES,ACAD UNIT RADIOTHERAPY & ONCOL,SUTTON SM2 5PX,SURREY,ENGLAND
关键词
STEREOTAXIC RADIOTHERAPY; LINEAR ACCELERATOR; DOSE-VOLUME DISTRIBUTION;
D O I
10.1016/0167-8140(91)90066-P
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
In order to establish the appropriate beam arrangement for use in stereotactic radiotherapy using a linear accelerator, dose volume distributions were calculated for a number of spherical targets in a head phantom and assessment was made by dose sparing of normal tissue outside the target volume. Using a single isocentre, fixed beam arrangements were compared with single and multiple non-coplanar isocentric arc rotations at target sizes from 10 to 55 mm diameter on a 6 MV Philips linear accelerator. From the dose-volume histograms produced, an arrangement of 3 or 4 arcs of rotation proved most suitable, in terms of sparing of normal tissue outside the target volume to high dose irradiation, across the range of target sizes studied. There was little further benefit with increasing the number of arcs beyond this. At target sizes greater than 20 mm diameter an arrangement of 6 static non-coplanar beams achieved sparing equivalent to multiple arc rotations and may have considerable advantages in the treatment of irregular volumes where customised beam shaping could be employed.
引用
收藏
页码:29 / 35
页数:7
相关论文
共 22 条
[1]  
BETTI O, 1983, NEUROCHIRURGIE, V29, P295
[2]   ULTRARAPID HIGH-DOSE IRRADIATION SCHEDULES FOR THE PALLIATION OF BRAIN METASTASES - FINAL RESULTS OF THE 1ST 2 STUDIES BY THE RADIATION-THERAPY ONCOLOGY GROUP [J].
BORGELT, B ;
GELBER, R ;
LARSON, M ;
HENDRICKSON, F ;
GRIFFIN, T ;
ROTH, R .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1981, 7 (12) :1633-1638
[3]   3-DIMENSIONAL PHOTON DOSE DISTRIBUTIONS WITH AND WITHOUT LUNG CORRECTIONS FOR TANGENTIAL BREAST INTACT TREATMENTS [J].
CHIN, LM ;
CHENG, CW ;
SIDDON, RL ;
RICE, RK ;
MIJNHEER, BJ ;
HARRIS, JR .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1989, 17 (06) :1327-1335
[4]   RELOCATABLE FRAME FOR STEREOTAXIC EXTERNAL BEAM RADIOTHERAPY [J].
GILL, SS ;
THOMAS, DGT ;
WARRINGTON, AP ;
BRADA, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 20 (03) :599-603
[5]   CEREBRAL RADIATION SURGERY USING MOVING FIELD IRRADIATION AT A LINEAR-ACCELERATOR FACILITY [J].
HARTMANN, GH ;
SCHLEGEL, W ;
STURM, V ;
KOBER, B ;
PASTYR, O ;
LORENZ, WJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1985, 11 (06) :1185-1192
[6]   STEREOTAXIC RADIOTHERAPY TECHNIQUE FOR SMALL INTRACRANIAL LESIONS [J].
HOUDEK, PV ;
FAYOS, JV ;
VANBUREN, JM ;
GINSBERG, MS .
MEDICAL PHYSICS, 1985, 12 (04) :469-472
[7]  
KJELLBERG RN, 1986, ANN CLIN RES, V18, P17
[8]   BRAGG-PEAK PROTON-BEAM THERAPY FOR ARTERIOVENOUS-MALFORMATIONS OF THE BRAIN [J].
KJELLBERG, RN ;
HANAMURA, T ;
DAVIS, KR ;
LYONS, SL ;
ADAMS, RD .
NEW ENGLAND JOURNAL OF MEDICINE, 1983, 309 (05) :269-274
[9]   SURVIVAL AND QUALITY OF LIFE AFTER INTERSTITIAL IMPLANTATION OF REMOVABLE HIGH-ACTIVITY I-125 SOURCES FOR THE TREATMENT OF PATIENTS WITH RECURRENT MALIGNANT GLIOMAS [J].
LEIBEL, SA ;
GUTIN, PH ;
WARA, WM ;
SILVER, PS ;
LARSON, DA ;
EDWARDS, MSB ;
LAMB, SA ;
HAM, B ;
WEAVER, KA ;
BARNETT, C ;
PHILLIPS, TL .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1989, 17 (06) :1129-1139
[10]  
LEKSELL L, 1951, ACTA CHIR SCAND, V102, P316