SAFETY OF CHANGING INTRAVENOUS DELIVERY SYSTEMS AT LONGER THAN 24-HOUR INTERVALS

被引:78
作者
BAND, JD
MAKI, DG
机构
[1] UNIV WISCONSIN HOSP, CTR HLTH SCI, DEPT MED, MADISON, WI 53706 USA
[2] UNIV WISCONSIN HOSP, CTR HLTH SCI, INFECT CONTROL UNIT, MADISON, WI 53706 USA
关键词
D O I
10.7326/0003-4819-91-2-173
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Routinely changing the i.v. delivery system (fluid containers and administration set) every 24 h is widely practiced in American hospitals to reduce the risk of [human] septicemia caused by contaminated infusate. A prospective clinical study was done to ascertain whether changing at longer intervals could be justified. At the conclusion of infusion therapy through 1 system, the cannula and an aliquot of remaining fluid were cultured quantitatively. Of 790 infusions, contaminated infusate was detected in 1 (0.39%) of 258 discontinued and sampled after 1-24 h of continuous use, 3 (0.84%) of 359 after 25-48 h and 1 (0.58%) of 173 after 49-71 h; none of these 5 contaminated systems produced septicemia. Five cannula-related septicemias were identified during the study, none associated with concordant contamination of infusate. Routinely replacing the delivery system every 48 h seems justified and could result in considerable savings to hospitals. Infection of the cannula wound and contamination of infusate seem unrelated.
引用
收藏
页码:173 / 178
页数:6
相关论文
共 38 条
  • [1] ANSCOMBE FI, 1978, BIOMETRIKA, V35, P246
  • [2] FAILURE OF DISPOSABLE DOMES TO PREVENT SEPTICEMIA ACQUIRED FROM CONTAMINATED PRESSURE TRANSDUCERS
    BUXTON, AE
    ANDERSON, RL
    KLIMEK, J
    QUINTILIANI, R
    [J]. CHEST, 1978, 74 (05) : 508 - 513
  • [3] CONTAMINATION OF INTRAVENOUS-INFUSION FLUID - EFFECTS OF CHANGING ADMINISTRATION SETS
    BUXTON, AE
    HIGHSMITH, AK
    GARNER, JS
    WEST, CM
    STAMM, WE
    DIXON, RE
    MCGOWAN, JE
    [J]. ANNALS OF INTERNAL MEDICINE, 1979, 90 (05) : 764 - 768
  • [4] EFFECT OF A MILLIPORE FILTER ON COMPLICATIONS OF INTRAVENOUS INFUSIONS - PROSPECTIVE CLINICAL TRIAL
    COLLIN, J
    TWEEDLE, DEF
    VENABLES, CW
    CONSTABLE, FL
    JOHNSTON, ID
    [J]. BMJ-BRITISH MEDICAL JOURNAL, 1973, 4 (5890): : 456 - 458
  • [5] FILTRATION AND INFUSION PHLEBITIS - DOUBLE-BLIND PROSPECTIVE CLINICAL-STUDY
    DELUCA, PP
    RAPP, RP
    BIVINS, B
    MCKEAN, HE
    GRIFFEN, WO
    [J]. AMERICAN JOURNAL OF HOSPITAL PHARMACY, 1975, 32 (10): : 1001 - 1007
  • [6] SEPTICEMIA FROM INTRAVENOUS INFUSIONS
    DUMA, RJ
    WARNER, JF
    DALTON, HP
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1971, 284 (05) : 257 - &
  • [7] SEPSIS CAUSED BY CONTAMINATED INTRAVENOUS FLUIDS - EPIDEMIOLOGIC, CLINICAL, AND LABORATORY INVESTIGATION OF AN OUTBREAK IN ONE HOSPITAL
    FELTS, SK
    SCHAFFNER, W
    MELLY, MA
    KOENIG, G
    [J]. ANNALS OF INTERNAL MEDICINE, 1972, 77 (06) : 881 - +
  • [8] FISHER EJ, 1971, 11 INT C ANT AG CHEM, P20
  • [9] FREEMAN JB, 1974, SURG GYNECOL OBSTET, V139, P905
  • [10] IMPORTANCE OF BETA, TYPE-II ERROR AND SAMPLE-SIZE IN DESIGN AND INTERPRETATION OF RANDOMIZED CONTROL TRIAL - SURVEY OF 71 NEGATIVE TRIALS
    FREIMAN, JA
    CHALMERS, TC
    SMITH, H
    KUEBLER, RR
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1978, 299 (13) : 690 - 694