THE OPTIMAL TECHNIQUE FOR ELECTRICAL CARDIOVERSION OF ATRIAL-FIBRILLATION

被引:43
作者
EWY, GA [1 ]
机构
[1] UNIV ARIZONA, COLL MED, DEPT MED, TUCSON, AZ 85724 USA
关键词
ATRIAL FIBRILLATION; ELECTRICAL CARDIOVERSION; TRANSTHORACIC RESISTANCE;
D O I
10.1002/clc.4960170207
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The optimal approach to electrical cardioversion of atrial fibrillation includes appropriate patient selection, anticoagulation, careful selection and monitoring of antiarrhythmic therapy, and proper electrical cardioversion technique. The optimal technique requires the use of metal electrodes, with one electrode of at least 8 cm in diameter placed in the anterior position, and the second of 12-13 cm diameter placed posteriorly just below the left scapulae, with generous amounts of the appropriate gel (such as Hewlett-Packard Redux Paste) as the electrode-skin interface and firm pressure to the paddle electrode with the patient in expiration. Thus the anterior-posterior chest diameter is decreased and less air between the electrodes is assured. The initial shock strength should be 200 J. The shock is synchronized with the electrocardiographic QRS complex. This report reviews the justification for these recommendations.
引用
收藏
页码:79 / 84
页数:6
相关论文
共 35 条
[1]  
[Anonymous], 1989, NEW ENGL J MED, V321, P406
[2]   ROLE OF PROPHYLACTIC ANTICOAGULATION FOR DIRECT-CURRENT CARDIOVERSION IN PATIENTS WITH ATRIAL-FIBRILLATION OR ATRIAL-FLUTTER [J].
ARNOLD, AZ ;
MICK, MJ ;
MAZUREK, RP ;
LOOP, FD ;
TROHMAN, RG .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 19 (04) :851-855
[3]   DEFIBRILLATOR ELECTRODE-CHEST WALL COUPLING AGENTS - INFLUENCE ON TRANS-THORACIC IMPEDANCE AND SHOCK SUCCESS [J].
AYLWARD, PE ;
KIESO, R ;
HITE, P ;
CHARBONNIER, F ;
KERBER, RE .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1985, 6 (03) :682-686
[4]   EFFICACY OF ANTICOAGULANT THERAPY IN PREVENTING EMBOLISM RELATED TO DC ELECTRICAL CONVERSION OF ATRIAL FIBRILLATION [J].
BJERKELUND, CJ ;
ORNING, OM .
AMERICAN JOURNAL OF CARDIOLOGY, 1969, 23 (02) :208-+
[5]   TRANSTHORACIC IMPEDANCE TO DEFIBRILLATOR DISCHARGE - EFFECT OF ELECTRODE SIZE AND ELECTRODE CHEST WALL INTERFACE [J].
CONNELL, PN ;
EWY, GA ;
DAHL, CF ;
EWY, MD .
JOURNAL OF ELECTROCARDIOLOGY, 1973, 6 (04) :313-317
[6]   EFFICACY AND SAFETY OF QUINIDINE THERAPY FOR MAINTENANCE OF SINUS RHYTHM AFTER CARDIOVERSION - A METAANALYSIS OF RANDOMIZED CONTROL TRIALS [J].
COPLEN, SE ;
ANTMAN, EM ;
BERLIN, JA ;
HEWITT, P ;
CHALMERS, TC .
CIRCULATION, 1990, 82 (04) :1106-1116
[7]  
Dahl C F, 1976, Med Instrum, V10, P151
[8]   MYOCARDIAL NECROSIS FROM DIRECT-CURRENT COUNTERSHOCK - EFFECT OF PADDLE ELECTRODE SIZE AND TIME INTERVAL BETWEEN DISCHARGES [J].
DAHL, CF ;
EWY, GA ;
WARNER, ED ;
THOMAS, ED .
CIRCULATION, 1974, 50 (05) :956-961
[9]   SHOULD TRANSESOPHAGEAL ECHOCARDIOGRAPHY BE USED TO GUIDE CARDIOVERSION [J].
DANIEL, WG .
NEW ENGLAND JOURNAL OF MEDICINE, 1993, 328 (11) :803-804
[10]  
DAWKIN PR, 1992, CIRCULATION, V19, pA201