摘要
An on-line preconcentration method utilizing a microcolumn of XAD-2 resin functionalized with 1-(2-thiazolylazo)-2-naphthol has been developed. Preconcentration factors of 125 were easily obtained for injection times of 5 min. The detection limit ranged between 2 ng l-1 for Mn and 40 ng l-1 for Ni. The resin has been used to preconcentrate Cd, Cu, Fe, Mn, Ni and Zn from river water and Antaretic sea-water (Ross Bay) prior to their determination by inductively coupled plasma atomic emission spectrometry. The precision of the technique is around 10% relative standard deviation at concentrations below the mu-g l-1 level and 5% for higher concentrations.
引用
收藏
页码:19 / 22
页数:4
相关论文
共 17 条
[1]   IMMOBILIZED 8-OXINE UNITS ON DIFFERENT SOLID SORBENTS FOR THE UPTAKE OF METAL TRACES [J].
ABOLLINO, O ;
MENTASTI, E ;
PORTA, V ;
SARZANINI, C .
ANALYTICAL CHEMISTRY, 1990, 62 (01) :21-26
[2]   DETERMINATION OF TRACE-METALS IN REFERENCE WATER STANDARDS BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY WITH ONLINE PRECONCENTRATION [J].
BEAUCHEMIN, D ;
BERMAN, SS .
ANALYTICAL CHEMISTRY, 1989, 61 (17) :1857-1862
[3]   FLOW-INJECTION ONLINE SORBENT EXTRACTION PRECONCENTRATION FOR GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY [J].
FANG, Z ;
SPERLING, M ;
WELZ, B .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1990, 5 (07) :639-646
[4]   FUNDAMENTAL AND PRACTICAL CONSIDERATIONS IN THE DESIGN OF ONLINE COLUMN PRECONCENTRATION FOR FLOW-INJECTION ATOMIC SPECTROMETRIC SYSTEMS [J].
FANG, ZL ;
XU, SK ;
ZHANG, SC .
ANALYTICA CHIMICA ACTA, 1987, 200 (01) :35-49
[5]   PERFORMANCE STUDIES UNDER FLOW CONDITIONS OF SILICA-IMMOBILIZED 8-QUINOLINOL AND ITS APPLICATION AS A PRECONCENTRATION TOOL IN FLOW-INJECTION ATOMIC-ABSORPTION DETERMINATIONS [J].
MARSHALL, MA ;
MOTTOLA, HA .
ANALYTICAL CHEMISTRY, 1985, 57 (03) :729-733
[6]   DETERMINATION OF TRACE-METALS IN SEAWATER BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY WITH PRECONCENTRATION ON SILICA-IMMOBILIZED 8-HYDROXYQUINOLINE [J].
MCLAREN, JW ;
MYKYTIUK, AP ;
WILLIE, SN ;
BERMAN, SS .
ANALYTICAL CHEMISTRY, 1985, 57 (14) :2907-2911
[7]  
MENTASTI E, 1989, ANN CHIM-ROME, V79, P629
[8]   PRE-CONCENTRATION EFFICIENCY OF CHELEX-100 RESIN FOR HEAVY-METALS IN SEAWATER .1. EFFECTS OF PH AND SALTS ON THE DISTRIBUTION RATIOS OF HEAVY-METALS [J].
PAI, SC ;
WHUNG, PY ;
LAI, RL .
ANALYTICA CHIMICA ACTA, 1988, 211 (1-2) :257-270
[9]  
PAI SC, 1988, ANAL CHIM ACTA, V211, P271
[10]  
PORTA V, UNPUB ANAL CHIM ACTA