摘要
The determination of arsenic, antimony and selenium by hydride generation and mercury by the cold vapour technique, following acid digestion of oily waste samples, can be very difficult if there is any residual organic matter. The preparation stage usually requires prolonged digestion to oxidize the organic matter. The situation is exacerbated if these metals are present as the organometallic derivatives. A method has been developed in which the organic matrices of oily waste samples, after solvent extraction, are completely oxidized. This has been achieved through the use of a newly designed microwave system that uses special high-pressure vessels capable of withstanding internal pressures in excess of 82.2 bar (1200 psi) (1 bar = 10(5) Pa). The relative standard deviation using organometallic standards ranged from 5.4 to 6.6% and the recoveries for four spiked oily waste samples ranged from 89 to 105%.
引用
收藏
页码:121 / 124
页数:4
相关论文
共 12 条
[1]   WET ASHING OF SOME BIOLOGICAL SAMPLES IN A MICROWAVE OVEN [J].
ABUSAMRA, A ;
MORRIS, JS ;
KOIRTYOHANN, SR .
ANALYTICAL CHEMISTRY, 1975, 47 (08) :1475-1477
[2]  
FISHER LB, 1986, ANAL CHEM, V58, P261
[3]   APPLICATION OF MASKING AGENTS IN MINIMIZING INTERFERENCES FROM SOME METAL-IONS IN DETERMINATION OF ARSENIC BY ATOMIC-ABSORPTION SPECTROMETRY WITH HYDRIDE GENERATION TECHNIQUE [J].
KIRKBRIGHT, GF ;
TADDIA, M .
ANALYTICA CHIMICA ACTA, 1978, 100 (SEP) :145-150
[4]   DIGESTION METHOD FOR THE DETERMINATION OF MERCURY IN VEGETABLE MATRICES BY COLD VAPOR ATOMIC-ABSORPTION SPECTROMETRY [J].
LANDI, S ;
FAGIOLI, F ;
LOCATELLI, C ;
VECCHIETTI, R .
ANALYST, 1990, 115 (02) :173-177
[5]  
MAY K, 1984, FRESEN Z ANAL CHEM, V317, P127
[6]  
Sinemus H. W., 1981, Atomic Spectroscopy, V2, P81
[8]   MECHANISMS OF TRANSITION-METAL INTERFERENCES IN HYDRIDE GENERATION ATOMIC-ABSORPTION SPECTROMETRY .1. INFLUENCE OF COBALT, COPPER, IRON AND NICKEL ON SELENIUM DETERMINATION [J].
WELZ, B ;
MELCHER, M .
ANALYST, 1984, 109 (05) :569-572
[10]   MECHANISMS OF TRANSITION-METAL INTERFERENCES IN HYDRIDE GENERATION ATOMIC-ABSORPTION SPECTROMETRY .3. RELEASING EFFECT OF IRON(III) ON NICKEL INTERFERENCE ON ARSENIC AND SELENIUM [J].
WELZ, B ;
MELCHER, M .
ANALYST, 1984, 109 (05) :577-579