ECHOPLANAR MR-IMAGING OF THE LIVER IN PATIENTS WITH FOCAL HEPATIC-LESIONS - QUANTITATIVE-ANALYSIS OF IMAGES MADE WITH VARIOUS PULSE SEQUENCES

被引:32
作者
SAINI, S [1 ]
REIMER, P [1 ]
HAHN, PF [1 ]
COHEN, MS [1 ]
机构
[1] HARVARD UNIV,SCH MED,BOSTON,MA 02114
关键词
D O I
10.2214/ajr.163.6.7992735
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. We undertook this study to evaluate pulse-sequence performance in terms of liver signal-to-noise ratio (SNR) and lesion-liver contrast-to-noise ratio (CNR) on T1- and Ta-weighted echoplanar MR imaging. SUBJECTS AND METHODS. Forty-nine patients referred for MR imaging of the liver were examined at 1.5 T with echoplanar MR imaging using spin-echo, inversion recovery, and gradient-echo pulse sequences. TP-weighted spin-echo (TE = 25, 50, 100, and 150 msec), T1-weighted inversion-recovery (T1 = 100, 380, 600, and 800 msec), and T2*-weighted gradient echo (TE = 20 msec) images were acquired after one excitation (TR = infinite), using a 128 x 128 data matrix. T2-weighted spin-echo (TE = 20, 50, 100, and 150 msec) images were also obtained with two excitations (TR = 6 sec), resulting in a 128 x 256 data matrix. Signal intensity measurements were made to calculate liver SNR and lesion-liver CNR. RESULTS. Single-excitation, TS-weighted, spin-echo images at a minimum TE of 25 msec provided the highest liver SNR (p < .05). Single-excitation, TP-weighted, spin-echo images at TEs of 50 and 100 msec, and T1-weighted inversion-recovery images at Tls of 100 and 380 msec provided the highest lesion-liver CNR (p < .05). However, the latter two pulse sequences had considerably inferior liver SNR (p < .05). CONCLUSION. Single-excitation, T2-weighted, spin-echo images provide both superior liver SNR and superior lesion-liver CNR. These results can be used to guide technique selection when echoplanar MR imaging is used to examine the liver.
引用
收藏
页码:1389 / 1393
页数:5
相关论文
共 14 条
[1]   MR ARTIFACTS - A REVIEW [J].
BELLON, EM ;
HAACKE, EM ;
COLEMAN, PE ;
SACCO, DC ;
STEIGER, DA ;
GANGAROSA, RE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1986, 147 (06) :1271-1281
[2]  
BUTTS K, 1993, RADIOLOGY, V189, P256
[3]   ULTRA-FAST IMAGING [J].
COHEN, MS ;
WEISSKOFF, RM .
MAGNETIC RESONANCE IMAGING, 1991, 9 (01) :1-37
[4]   ECHO-PLANAR PEDIATRIC IMAGER [J].
CROOKS, LE ;
ARAKAWA, M ;
HYLTON, NM ;
AVRAM, H ;
HOENNINGER, JC ;
WATTS, JC ;
HALE, JD ;
KAUFMAN, L .
RADIOLOGY, 1988, 166 (01) :157-163
[5]   MR ANGIOGRAPHY [J].
EDELMAN, RR ;
MATTLE, HP ;
ATKINSON, DJ ;
HOOGEWOUD, HM .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 154 (05) :937-946
[6]  
FERRUCCI JT, 1987, AJR, V147, P1103
[7]   MR ANGIOGRAPHY OF THE PORTAL AND HEPATIC VENOUS SYSTEMS - PRELIMINARY EXPERIENCE WITH ECHOPLANAR IMAGING [J].
GOLDBERG, MA ;
YUCEL, EK ;
SAINI, S ;
HAHN, PF ;
KAUFMAN, JA ;
COHEN, MS .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (01) :35-40
[8]   VALUE OF T1-RELAXATION AND T2-RELAXATION TIMES FROM ECHOPLANAR MR IMAGING IN THE CHARACTERIZATION OF FOCAL HEPATIC-LESIONS [J].
GOLDBERG, MA ;
HAHN, PF ;
SAINI, S ;
COHEN, MS ;
REIMER, P ;
BRADY, TJ ;
MUELLER, PR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (05) :1011-1017
[9]   MULTI-PLANAR IMAGE-FORMATION USING NMR SPIN ECHOES [J].
MANSFIELD, P .
JOURNAL OF PHYSICS C-SOLID STATE PHYSICS, 1977, 10 (03) :L55-L58
[10]  
PYKETT IL, 1987, MAGNET RESON MED, V5, P563