COLOR DOPPLER REGURGITANT CHARACTERISTICS OF NORMAL MECHANICAL MITRAL-VALVE PROSTHESES INVITRO

被引:11
作者
BAUMGARTNER, H
KHAN, S
DEROBERTIS, M
CZER, L
MAURER, G
机构
[1] CEDARS SINAI MED CTR,DIV CARDIOL & CARDIOVASC SURG,LOS ANGELES,CA 90048
[2] UNIV CALIF LOS ANGELES,SCH MED,LOS ANGELES,CA 90024
关键词
MECHANICAL HEART VALVES; NORMAL REGURGITATION; COLOR DOPPLER;
D O I
10.1161/01.CIR.85.1.323
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. To evaluate normal regurgitant characteristics of St. Jude (SJ) and Medtronic-Hall (MH) mitral valves, four sizes (25-31 mm) of each were studied in a pulsatile flow model. Methods and Results. Regurgitant flow was measured by flowmeter at left ventricular pressures of 80, 130, and 180 mm Hg. Peak regurgitant flow rates ranged from 6.2 to 12.7 cm3/sec in SJ valves and from 7.9 to 17.5 cm3/sec in MH valves. Regurgitant orifice areas calculated from the Doppler continuity equation ranged from 1.6 to 2.0 mm2 in SJ valves and from 2.2 to 2.9 mm2 in MH valves. Regurgitant volumes across the closed valve at a left ventricular pressure of 130 mm Hg were normalized to an ejection time of 280 msec and ranged from 1.5 to 1.9 cm3 in SJ valves and from 2.1 to 2.8 cm3 in MH valves. Jets were imaged by color Doppler in six rotational planes, and jet size and morphology were compared with those of regurgitant jets from circular orifices with sizes comparable to the calculated prosthetic valve regurgitant orifices (1.1-3.1 mm2). SJ valves showed two converging jets from the pivot points, one central jet, and a variable number of peripheral jets. The mean color jet area derived from the six image planes ranged from 1.6 to 5.3 cm2. Aliasing occurred only close to the valve (maximal distance 0.5-2.0 cm). MH valves showed a large central jet with a maximal length of aliased flow between 2.0 and 5.5 cm. Depending on valve size, driving pressure, and image plane, one or two small peripheral jets were found. These jets did not show aliasing in any case. The mean color jet area ranged from 5.1 to 11.0 cm2. Jets originating from circular orifices of comparable size showed jet areas from 5.5 to 13.9 cm2 and aliasing distances from 3.3 to 7.3 cm. At similar regurgitant orifice areas, driving pressures, and regurgitant flows, the measured color areas and aliasing distances were smallest in SJ valves, larger in MH valves, and largest in simple circular orifices. Conclusions. Large, complex regurgitant jets can be found in normal closed SJ and MH valves by color Doppler, although regurgitant flow volume is minimal. Jet size and velocity distribution differs markedly between SJ valves, MH valves, and circular orifices, even with comparable driving pressure, regurgitant orifice area, and regurgitant volume. The characteristic patterns of normal regurgitation must be recognized to avoid incorrect diagnoses of pathological regurgitation in SJ and MH prosthetic valves. MH valves should not be removed solely on the basis of a central regurgitant jet with a long aliasing distance. Peripheral jets in MH valves and all jets in SJ valves should be considered normal as long as no or only minimal aliasing is present. In contrast, peripheral jets with significant aliasing may represent strong evidence of pathological regurgitation.
引用
收藏
页码:323 / 332
页数:10
相关论文
共 23 条
[1]   COLOR FLOW DOPPLER EVALUATION OF ST-JUDE MEDICAL PROSTHETIC VALVES [J].
ALAM, M ;
ROSMAN, HS ;
MCBROOM, D ;
GRAHAM, L ;
MAGILLIGAN, DJ ;
KHAJA, F ;
STEIN, PD .
AMERICAN JOURNAL OF CARDIOLOGY, 1989, 64 (19) :1387-1389
[2]   DISCREPANCIES BETWEEN DOPPLER AND CATHETER GRADIENTS IN AORTIC PROSTHETIC VALVES INVITRO - A MANIFESTATION OF LOCALIZED GRADIENTS AND PRESSURE RECOVERY [J].
BAUMGARTNER, H ;
KHAN, S ;
DEROBERTIS, M ;
CZER, L ;
MAURER, G .
CIRCULATION, 1990, 82 (04) :1467-1475
[3]   COMPUTER-ANALYSIS OF DOPPLER COLOR FLOW MAPPING IMAGES FOR QUANTITATIVE ASSESSMENT OF INVITRO FLUID JETS [J].
BOLGER, AF ;
EIGLER, NL ;
PFAFF, JM ;
RESSER, KJ ;
MAURER, G .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1988, 12 (02) :450-457
[4]   A NEW METHOD FOR NONINVASIVE QUANTIFICATION OF VALVULAR REGURGITATION BASED ON CONSERVATION OF MOMENTUM - INVITRO VALIDATION [J].
CAPE, EG ;
SKOUFIS, EG ;
WEYMAN, AE ;
YOGANATHAN, AP ;
LEVINE, RA .
CIRCULATION, 1989, 79 (06) :1343-1353
[5]   EVALUATION OF NORMAL PROSTHETIC VALVE FUNCTION BY DOPPLER ECHOCARDIOGRAPHY [J].
COOPER, DM ;
STEWART, WJ ;
SCHIAVONE, WA ;
LOMBARDO, HP ;
LYTLE, BW ;
LOOP, FD ;
SALCEDO, EE .
AMERICAN HEART JOURNAL, 1987, 114 (03) :576-582
[6]   REGURGITATION OF PROSTHETIC HEART-VALVES - DEPENDENCE ON HEART-RATE AND CARDIAC-OUTPUT [J].
DELLSPERGER, KC ;
WIETING, DW ;
BAEHR, DA ;
BARD, RJ ;
BRUGGER, JP ;
HARRISON, EC .
AMERICAN JOURNAL OF CARDIOLOGY, 1983, 51 (02) :321-328
[7]   EVALUATION OF BJORK-SHILEY PROSTHETIC VALVES BY REAL-TIME TWO-DIMENSIONAL DOPPLER ECHOCARDIOGRAPHIC FLOW MAPPING [J].
DITTRICH, H ;
NICOD, P ;
HOIT, B ;
DALTON, N ;
SAHN, D .
AMERICAN HEART JOURNAL, 1988, 115 (01) :133-138
[8]  
FLACHSKAMPF FA, 1990, J AM COLL CARDIOL S, V15, P89
[9]   DOPPLER COLOR FLOW MAPPING IN THE EVALUATION OF PROSTHETIC MITRAL AND AORTIC-VALVE FUNCTION [J].
KAPUR, KK ;
FAN, P ;
NANDA, NC ;
YOGANATHAN, AP ;
GOYAL, RG .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 13 (07) :1561-1571
[10]  
KNOTT E, 1988, J THORAC CARDIOV SUR, V96, P952