ILIAC ARTERIES - REANALYSIS OF RESULTS OF BALLOON ANGIOPLASTY

被引:180
作者
JOHNSTON, KW [1 ]
机构
[1] UNIV TORONTO,DEPT SURG,TORONTO M5S 1A1,ONTARIO,CANADA
关键词
ARTERIES; EXTREMITIES; STENOSIS OR OBSTRUCTION; TRANSLUMINAL ANGIOPLASTY;
D O I
10.1148/radiology.186.1.8416566
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In this reanalysis of the 667 percutaneous transluminal balloon angioplasties (PTAs) of the iliac arteries, the variables that are predictive of early and late success were identified. For 82 iliac occlusions, the success rate at 1 month was 75.6% +/- 4.7 (mean +/- standard error). With exclusion of the 15 technical failures that were associated with one complication, the success rate at 1 month was 91.0% +/- 3.5 and at 3 years, 58.8% +/- 7.1. For PTA of an iliac occlusion at one site, the predicted 3-year success rate was 66%, whereas for PTA of an iliac occlusion with a tandem lesion, the success rate was 17%. For the 313 common iliac PTAs, the success rate at 1 month was 97.1% +/- 0.9; at 1 year, 81.1% +/- 2.3; at 2 years, 70.6% +/- 2.9; at 3 years, 67.8% +/- 3.0, at 4 years, 64.9% +/- 3.3; at 5 years, 60.2% +/- 4.0; and at 6 years, 52.0% +/- 5.7. There were no variables that were statistically predictive of late results. For the 209 external iliac PTAs, the predicted 3-year success rate was 57% for men and 34% for women. For 58 PTAs of both common and external iliac stenoses, the predicted 3-year success rate was 73% for patients with good runoff and 30% for those with poor runoff. Serious complications were recorded in 3.9% (26 of 667): Death occurred in 0.3%, operation was necessary in 1.0%, and hospital discharge was delayed in 2.6%.
引用
收藏
页码:207 / 212
页数:6
相关论文
共 21 条
[1]  
CAMBRIA RP, 1987, ARCH SURG-CHICAGO, V122, P283
[2]  
COLDMAN AJ, 1979, CAN MED ASSOC J, V121, P1065
[3]   TRANS-LUMINAL ANGIOPLASTY OF THE ILIAC AND FEMORAL ARTERIES - FOLLOW-UP RESULTS WITHOUT ANTICOAGULATION [J].
FREIMAN, DB ;
SPENCE, R ;
GATENBY, R ;
GERTNER, M ;
ROBERTS, B ;
BERKOWITZ, HD ;
RING, EJ ;
OLEAGA, JA .
RADIOLOGY, 1981, 141 (02) :347-350
[4]   PERCUTANEOUS TRANS-LUMINAL ANGIOPLASTY OF THE ARTERIES OF THE LOWER-LIMBS - A 5 YEAR FOLLOW-UP [J].
GALLINO, A ;
MAHLER, F ;
PROBST, P ;
NACHBUR, B .
CIRCULATION, 1984, 70 (04) :619-623
[5]  
GRAZIANI L, 1987, EUR J RADIOL, V7, P91
[6]   TECHNIQUE OF PERCUTANEOUS TRANS-LUMINAL ANGIOPLASTY WITH THE GRUNTZIG BALLOON CATHETER [J].
GRUNTZIG, A ;
KUMPE, DA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1979, 132 (04) :547-552
[7]   5-YEAR RESULTS OF A PROSPECTIVE-STUDY OF PERCUTANEOUS TRANS-LUMINAL ANGIOPLASTY [J].
JOHNSTON, KW ;
RAE, M ;
HOGGJOHNSTON, SA ;
COLAPINTO, RF ;
WALKER, PM ;
BAIRD, RJ ;
SNIDERMAN, KW ;
KALMAN, P .
ANNALS OF SURGERY, 1987, 206 (04) :403-413
[8]   FEMORAL AND POPLITEAL ARTERIES - REANALYSIS OF RESULTS OF BALLOON ANGIOPLASTY [J].
JOHNSTON, KW .
RADIOLOGY, 1992, 183 (03) :767-771
[9]  
JORGENSEN B, 1988, ACTA CHIR SCAND, V154, P647
[10]  
KADIR S, 1983, SURGERY, V94, P10