OBSERVATIONS OF CORONARY FLOW AUGMENTATION AND BALLOON FUNCTION DURING INTRAAORTIC BALLOON COUNTERPULSATION USING TRANSESOPHAGEAL ECHOCARDIOGRAPHY

被引:32
作者
KATZ, ES
TUNICK, PA
KRONZON, I
机构
[1] Department of Medicine, New York University Medical Center, New York, NY
关键词
D O I
10.1016/0002-9149(92)90716-C
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The intraaortic balloon pump has been shown to decrease myocardial oxygen demand by afterload reduction, while increasing myocardial oxygen supply by diastolic augmentation of coronary blood flow. This diastolic augmentation of coronary flow has been demonstrated experimentally with invasive methods. Noninvasively, transesophageal echocardiography has demonstrated efficacy in enabling visualization of the proximal left coronary artery and in recording coronary blood flow velocity. To assess the potential of this technique in demonstrating quantitatively the increase in coronary flow during counterpulsation, 6 patients were studied during intermittent balloon pumping. Peak diastolic coronary blood flow velocity increased by a mean of 117% (range 62 to 287) during balloon inflation (p = 0.002). Furthermore, coronary flow velocity integral increased by a mean of 87% (range 43 to 176; p = 0.003). Problems associated with intraaortic balloon pumping were discovered by transesophageal echocardiography in 4 patients (incorrect balloon placement, damage to the aortic wall [2 patients], and premature balloon deflation time). Transesophageal echocardiography can be used in evaluating intraaortic balloon positioning within the aorta and in monitoring coronary artery flow augmentation during counterpulsation. This relatively noninvasive technique adds another dimension to the evaluation of balloon function and may help in optimizing the benefits of counterpulsation.
引用
收藏
页码:1635 / 1639
页数:5
相关论文
共 27 条
[1]   RESULTS AND COMPLICATIONS OF INTRA-AORTIC BALLOON COUNTERPULSATION [J].
BECKMAN, CB ;
GEHA, AS ;
HAMMOND, GL ;
BAUE, AE .
ANNALS OF THORACIC SURGERY, 1977, 24 (06) :550-559
[2]   PERCUTANEOUS INTRA-AORTIC BALLOON PUMPING - INITIAL CLINICAL-EXPERIENCE [J].
BREGMAN, D ;
CASARELLA, WJ .
ANNALS OF THORACIC SURGERY, 1980, 29 (02) :153-155
[3]   CLINICAL AND HEMODYNAMIC RESULTS OF INTRAAORTIC BALLOON PUMPING AND SURGERY FOR CARDIOGENIC-SHOCK [J].
DUNKMAN, WB ;
BUCKLEY, MJ ;
AUSTEN, WG ;
SANDERS, CA ;
KANTROWITZ, AR ;
MUNDTH, ED ;
LEINBACH, RC .
CIRCULATION, 1972, 46 (03) :465-+
[4]   INTRAAORTIC BALLOON PUMPING IN EXPERIMENTAL ANIMAL - EFFECTS AND PROBLEMS [J].
FEOLA, M ;
ADACHI, M ;
AKERS, WW ;
ROSS, JN ;
WIETING, DW ;
KENNEDY, JH .
AMERICAN JOURNAL OF CARDIOLOGY, 1971, 27 (02) :129-&
[5]   AUGMENTATION OF REGIONAL CORONARY BLOOD-FLOW BY INTRA-AORTIC BALLOON COUNTERPULSATION IN PATIENTS WITH UNSTABLE ANGINA [J].
FUCHS, RM ;
BRIN, KP ;
BRINKER, JA ;
GUZMAN, PA ;
HEUSER, RR ;
YIN, FCP .
CIRCULATION, 1983, 68 (01) :117-123
[6]  
HARVEY JC, 1981, CIRCULATION, V64, P114
[7]   INTRA-AORTIC BALLOON PUMPING - THEORY AND PRACTICE - EXPERIENCE WITH 325 PATIENTS [J].
IGO, SR ;
HIBBS, CW ;
TRONO, R ;
FUQUA, JM ;
EDMONDS, CH ;
LEACHMAN, CJ ;
BREWER, MA ;
HOLUB, DA ;
NORMAN, JC .
ARTIFICIAL ORGANS, 1978, 2 (03) :249-256
[8]   TRANSESOPHAGEAL DOPPLER ECHOCARDIOGRAPHY EVALUATION OF CORONARY BLOOD-FLOW VELOCITY IN BASE-LINE CONDITIONS AND DURING DIPYRIDAMOLE-INDUCED CORONARY VASODILATION [J].
ILICETO, S ;
MARANGELLI, V ;
MEMMOLA, C ;
RIZZON, P .
CIRCULATION, 1991, 83 (01) :61-69
[9]   COMPLICATIONS OF THE INTRA-AORTIC BALLOON COUNTERPULSATION DEVICE - CLINICAL AND MORPHOLOGIC OBSERVATIONS IN 45 NECROPSY PATIENTS [J].
ISNER, JM ;
COHEN, SR ;
VIRMANI, R ;
LAWRINSON, W ;
ROBERTS, WC .
AMERICAN JOURNAL OF CARDIOLOGY, 1980, 45 (02) :260-268
[10]   INITIAL CLINICAL EXPERIENCE WITH INTRAAORTIC BALLOON PUMPING IN CARDIOGENIC SHOCK [J].
KANTROWITZ, A ;
TJONNELAND, S ;
FREED, PS ;
PHILLIPS, SJ ;
BUTNER, AN ;
SHERMAN, JL .
JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1968, 203 (02) :113-+