A PROSPECTIVE EVALUATION OF PLASMA-TFE AND EXPANDED PTFE GRAFTS FOR ROUTINE AND EARLY USE AS VASCULAR ACCESS DURING HEMODIALYSIS

被引:13
作者
HELLING, TS [1 ]
NELSON, PW [1 ]
SHELTON, L [1 ]
机构
[1] UNIV MISSOURI,SCH MED,DEPT SURG,KANSAS CITY,MO 64108
关键词
D O I
10.1097/00000658-199211000-00012
中图分类号
R61 [外科手术学];
学科分类号
摘要
The use of prosthetic grafts as vascular access for chronic hemodialysis is frequently necessary in patients with end-stage renal disease. Most commonly, expanded polytetrafluoroethylene (e-PTFE) has been employed because of ease of handling, tissue inertness, and acceptable long-term patency. Delay in use to allow for tissue ingrowth, however, has often required placement of temporary access devices. The authors have undertaken evaluation of a new material, plasma polymerized woven dacron Plasma-TFE, in a prospective randomized trial (Plasma-TFE VA) to compare clinical behavior against e-PTFE grafts, and we have used the Plasma-TFE grafts in an additional group of patients (Plasma-TFE AVA) as early access (within 1 week of implantation). Twenty-one Plasma-TFE grafts were implanted in 19 patients and 19 e-PTFE grafts were implanted in 17 patients in a prospective randomized fashion. Additionally, 31 Plasma-TFE grafts were implanted in 31 nonrandomized patients for early access. Primary patency rates in Plasma-TFE VA and e-PTFE grafts were equivalent at 12 months (0.471 and 0.556). When Plasma-TFE AVA primary patency was included (0.621), comparisons were not statistically significant (p = 0.50). Similarly, secondary patency rates among the three groups did not differ (cumulative proportion patent at 12 months: Plasma-TFE VA 0.403, e-PTFE 0.658, Plasma-TFE AVA 0.510). In considering after-revision patency after graft thrombosis, however, the Plasma-TFE grafts (both VA and AVA) performed significantly more poorly (p = 0.027) than e-PTFE grafts. Incidence of graft infection, wound infection, arm edema, hematoma from use, and occurrence of distal limb ischemia between Plasma-TFE (VA and AVA) and e-PTFE did not differ statistically. The authors conclude that Plasma-TFE compares favorably to e-PTFE with respect to primary and secondary patency and nonthrombotic complications, even with early use. Plasma-TFE does not perform as well as e-PTFE, however, after graft thrombosis.
引用
收藏
页码:596 / 599
页数:4
相关论文
共 19 条
[1]   SUBCLAVIAN STENOSIS - A MAJOR COMPLICATION OF SUBCLAVIAN DIALYSIS CATHETERS [J].
BARRETT, N ;
SPENCER, S ;
MCIVOR, J ;
BROWN, EA .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 1988, 3 (04) :423-425
[2]   CHRONIC HEMODIALYSIS USING VENIPUNCTURE AND A SURGICALLY CREATED ARTERIOVENOUS FISTULA [J].
BRESCIA, MJ ;
CIMINO, JE ;
APPEL, K ;
HURWICH, BJ .
NEW ENGLAND JOURNAL OF MEDICINE, 1966, 275 (20) :1089-&
[3]  
CANIZALES S, 1989, CAN J SURG, V32, P433
[4]  
DORNER DB, 1982, SURGERY, V91, P712
[5]  
DUNN J, 1987, SURGERY, V102, P784
[6]  
ETHEREDGE EE, 1983, SURGERY, V94, P464
[7]   LATE VASCULAR COMPLICATIONS OF THE SUBCLAVIAN DIALYSIS CATHETER [J].
FANT, GF ;
DENNIS, VW ;
QUARLES, LD .
AMERICAN JOURNAL OF KIDNEY DISEASES, 1986, 7 (03) :225-228
[8]   GRAFT GEOMETRY AND VENOUS INTIMAL-MEDIAL HYPERPLASIA IN ARTERIOVENOUS LOOP GRAFTS [J].
FILLINGER, MF ;
REINITZ, ER ;
SCHWARTZ, RA ;
RESETARITS, DE ;
PASKANIK, AM ;
BRUCH, D ;
BREDENBERG, CE .
JOURNAL OF VASCULAR SURGERY, 1990, 11 (04) :556-566
[9]   COMPARISON OF AUTOGENOUS FISTULA VERSUS EXPANDED POLYTETRAFLUOROETHYLENE GRAFT FISTULA FOR ANGIOACCESS IN HEMODIALYSIS [J].
KHERLAKIAN, GM ;
ROEDERSHEIMER, LR ;
ARBAUGH, JJ ;
NEWMARK, KJ ;
KING, LR .
AMERICAN JOURNAL OF SURGERY, 1986, 152 (02) :238-243
[10]  
Parker N R, 1989, J Invest Surg, V2, P457, DOI 10.3109/08941938909018271