ON THE PERFORMANCE OF REGRESSION AND STEP-INITIALIZED IIR CLUTTER FILTERS FOR COLOR DOPPLER SYSTEMS IN DIAGNOSTIC MEDICAL ULTRASOUND

被引:95
作者
KADI, AP
LOUPAS, T
机构
[1] Ultrasonics Laboratory, Division of Radiophysics, CSIRO Australia, Chatswood
关键词
D O I
10.1109/58.464825
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
One of the major issues in color Doppler ultrasound is the suppression of clutter that arises from stationary or slowly moving tissue. If not adequately suppressed, clutter can severely affect the ability of color Doppler systems to accurately estimate the Doppler mean frequency and power of blood, resulting in a potentially misleading depiction of flow. In this study, the performances of two classes of clutter suppression techniques-step-initialized infinite impulse response (IIR) and regression filters-were evaluated and compared by means of extensive simulations. The performance indicators used were the accuracy and precision of the mean frequency and the power estimates after clutter filtering. In summary, the ability of both filter classes to suppress clutter was found to vary considerably depending on factors such as the clutter-to-flow-signal ratio and the ensemble length. In particular, the performance of step-initialized IIR filters was shown to be noticeably inferior to that predicted by their steady-state response. Regression filters were found to offer significantly better performance than step-initialized IIR filters under heavy clutter conditions acid, given their steeper roll off, appear to be more effective clutter suppressors for power Doppler imaging. However, it should be noted that, as demonstrated by the simulations, the performance of IIR filters is severely degraded by their transient response which, in turn, is determined by the initialization scheme used. Therefore, more elaborate schemes-with superior transient characteristics than step-initialization-could significantly improve the effectiveness of IIR filtering under heavy clutter conditions.
引用
收藏
页码:927 / 937
页数:11
相关论文
共 21 条
[1]   INITIALIZATION FOR IMPROVED IIR FILTER PERFORMANCE [J].
CHORNOBOY, ES .
IEEE TRANSACTIONS ON SIGNAL PROCESSING, 1992, 40 (03) :543-550
[2]  
Evans D. H., 1989, DOPPLER ULTRASOUND P
[3]   INITIALIZATION TECHNIQUE FOR IMPROVED MTI PERFORMANCE IN PHASED-ARRAY RADARS [J].
FLETCHER, RH ;
BURLAGE, DW .
PROCEEDINGS OF THE IEEE, 1972, 60 (12) :1551-1552
[4]  
Gold B., 1969, DIGITAL PROCESSING S
[5]  
HALDBERG LI, 1986, HEWLETTPACKARD J, V37, P35
[6]  
HOECKS APG, 1991, ULTRASONIC IMAGING, V13, P135
[7]   REAL-TIME TWO-DIMENSIONAL BLOOD-FLOW IMAGING USING AN AUTO-CORRELATION TECHNIQUE [J].
KASAI, C ;
NAMEKAWA, K ;
KOYANO, A ;
OMOTO, R .
IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1985, 32 (03) :458-464
[8]   AN APPROACH TO DIGITAL SIGNAL-PROCESSING FOR ULTRASONICS RESEARCH [J].
KNIGHT, PC ;
ROBINSON, DE .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1987, 13 (06) :345-352
[9]  
Lim J.S., 1990, 2 DIMENSIONAL SIGNAL
[10]   EXPERIMENTAL EVALUATION OF VELOCITY AND POWER ESTIMATION FOR ULTRASOUND BLOOD-FLOW IMAGING, BY MEANS OF A 2-DIMENSIONAL AUTOCORRELATION APPROACH [J].
LOUPAS, T ;
PETERSON, RB ;
GILL, RW .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1995, 42 (04) :689-699