USE OF AN INDOOR AIR-QUALITY MODEL (IAQM) TO ESTIMATE INDOOR OZONE LEVELS

被引:72
作者
HAYES, SR [1 ]
机构
[1] SYST APPLICAT INC,SAN RAFAEL,CA
来源
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION | 1991年 / 41卷 / 02期
关键词
D O I
10.1080/10473289.1991.10466833
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Currently, outdoor ozone levels in many U.S. cities exceed the primary health-based national ambient air quality standard. While outdoor ozone levels are an important measure of the severity of those exceedances, people typically spend more than 80 percent of their time indoors, where ozone levels are lower. Indoor ozone levels range from 10 to 80 percent of outdoor levels, with many people receiving a substantial portion of their ozone exposure while indoors. This paper uses an indoor air quality model (IAQM) to estimate indoor ozone levels by microenvironment type (home, office, and vehicle) and configuration (windows open, windows closed, older construction, weatherized, and air conditioned). The formulation of IAQM is discussed, along with specification of model parameters for ozone. The multi-compartment version of IAQM is described, with a single-compartment version used for the analyses. IAQM-calculated ozone indoor-outdoor ratios compare well with research-reported values. Results indicate that ozone peak-concentration indoor-outdoor ratios range as follows: home-0.65 (windows open), 0.36 (air conditioned), 0.23 (typical construction, windows closed), and 0.05 (energy-efficient construction, windows closed); office-0.82 (heating, ventilation and air conditioning systems supplying 100 percent outdoor air), 0.60 (typical HVAC), and 0.32 (energy-efficient HVAC); and vehicle-0.41 (85 mph), 0.33 (55 mph), and 0.21 (10 mph). Analysis results are presented to characterize IAQM's sensitivity to assumed model parameters.
引用
收藏
页码:161 / 170
页数:10
相关论文
共 35 条
[21]   MEASUREMENTS OF POLLUTANTS INSIDE AN AUTOMOBILE [J].
PETERSEN, GA ;
SABERSKY, RH .
JOURNAL OF THE AIR POLLUTION CONTROL ASSOCIATION, 1975, 25 (10) :1028-1032
[22]  
RODDIN MF, 1979, SRI INT, V1
[23]  
RODDIN MF, 1979, SRI INT, V2
[24]   CONCENTRATIONS, DECAY RATES, AND REMOVAL OF OZONE AND THEIR RELATION TO ESTABLISHING CLEAN INDOOR AIR [J].
SABERSKY, RH ;
SINEMA, DA ;
SHAIR, FH .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1973, 7 (04) :347-353
[25]   THEORETICAL MODEL FOR RELATING INDOOR POLLUTANT CONCENTRATIONS TO THOSE OUTSIDE [J].
SHAIR, FH ;
HEITNER, KL .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1974, 8 (05) :444-451
[26]   OZONE AND THE DETERIORATION OF WORKS OF ART [J].
SHAVER, CL ;
CASS, GR ;
DRUZIK, JR .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1983, 17 (12) :748-752
[27]  
SPARKS LE, 1988, EPA600888097A
[28]  
THOMPSON CR, 1973, JAPCA-INT J AIR POLL, V19, P881
[29]  
TURK A, 1963, ASHRAE J, V5, P55
[30]  
WECHSLER CJ, 1989, JAPCA-INT J AIR POLL, V39, P1562