MICROSCOPE-BASED MULTIPARAMETER LASER SCANNING CYTOMETER YIELDING DATA COMPARABLE TO FLOW-CYTOMETRY DATA

被引:216
作者
KAMENTSKY, LA
KAMENTSKY, LD
机构
[1] Compucyte Corporation, Cambridge, Massachusetts
来源
CYTOMETRY | 1991年 / 12卷 / 05期
关键词
KINETIC CYTOMETRY; DATA ANALYSIS; DNA CYTOMETRY;
D O I
10.1002/cyto.990120502
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We describe a computer-controlled 10-mu-m spot size laser scanning cytometer for making multiple wavelength fluorescence and scatter measurements of unconstrained cells on a surface such as a microscope slide. Designated areas of slides placed on a microscope stage are automatically scanned, and cells which generate above-threshold scatter or fluorescence values are found and individually processed to determine a list of measurement parameters. For each fluorescence or scatter measurement parameter, this list contains the integrated and peak values and bit pattern images of a scan window centered on the cell. The measurement time, the position of the cell on the slide, and two segmentation indices are also included in the list. Measurement time, cell position, and properties derived from the bit patterns are used interchangeably with integrated or peak measurement values as coordinates of multiproperty displays. Cells may be selected for counting, data display in various forms, or visual observation based on their meeting complex criteria among a chain of two property screens. Cells with selected properties may be viewed during an experiment or retrospectively. A designated specimen field may be repeatedly remeasured to perform kinetic cell studies. An argon ion and a HeNe- based laser instrument have been constructed and software has been written and evaluated with the specific goal of increasing the precision of propidium iodide-stained cellular DNA measurements. Some of the capabilities of the instrument and its current performance are described.
引用
收藏
页码:381 / 387
页数:7
相关论文
共 13 条
[1]  
BODDINGTON MM, 1967, BMJ-BRIT MED J, V3, P160
[2]   ACOUSTOOPTIC LASER-SCANNING CYTOMETER [J].
BURGER, D ;
GERSHMAN, R .
CYTOMETRY, 1988, 9 (02) :101-110
[3]   CESAR - CERVICAL SMEAR ANALYSER AND READER - A NEW APPROACH TO EVALUATING CELLS IN CYTOLOGICAL PREPARATIONS [J].
DAWSON, IMP ;
HEANLEY, CP ;
HEBERPER.AC ;
TYLKO, JK .
JOURNAL OF CLINICAL PATHOLOGY, 1967, 20 (05) :724-&
[4]  
DEGROOTH BG, 1985, CYTOMETRY, V6, P226
[5]   DEVELOPMENT OF VIBRATING-MIRROR FLYING SPOT MICROSCOPE FOR ULTRAVIOLET SPECTROPHOTOMETRY [J].
FREED, JJ ;
ENGLE, JL .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1962, 97 (02) :412-&
[6]   PRACTICAL APPLICATION OF COMPUTER PATTERN-RECOGNITION RESEARCH - ABBOTT ADC-500 DIFFERENTIAL CLASSIFIER [J].
GREEN, JE .
JOURNAL OF HISTOCHEMISTRY & CYTOCHEMISTRY, 1979, 27 (01) :160-173
[7]  
HART L, 1990, ANAL QUANT CYTOL, V12, P127
[8]  
MANSBERG HP, 1969, ANN NY ACAD SCI, V157, P5
[9]   A MICROFLUOROMETRIC SCANNER FOR THE DIFFERENTIAL DETECTION OF CELLS - APPLICATION TO EXFOLIATIVE CYTOLOGY [J].
MELLORS, RC ;
SILVER, R .
SCIENCE, 1951, 114 (2962) :356-360
[10]  
READ JS, 1979, TUTORIALS CYTOLOGY I, P143