DEVELOPING GLUCOSE SENSORS FOR IN-VIVO USE

被引:41
作者
PICKUP, J
机构
关键词
D O I
10.1016/0167-7799(93)90016-3
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
The potential uses for in vivo glucose sensors in patients with diabetes mellitus include an alarm for low blood-glucose concentrations, a continuous read-out of glucose levels and as part of a feedback-controlled insulin delivery system (artificial pancreas). Most experience has been with implanted amperometric enzyme electrodes, though sensors based on field-effect transistors (FETs) show promise for the future. Sensing responses at the subcutaneous site correlate with plasma-glucose values, but there are often problems of calibration and drift. Implantable glucose sensors are not therefore in routine clinical use. Non-invasive glucose sensing based on near-infrared spectroscopy is being actively investigated as an alternative strategy.
引用
收藏
页码:285 / 291
页数:7
相关论文
共 34 条
  • [1] ABEL P, 1984, BIOMED BIOCHIM ACTA, V43, P577
  • [2] AMPEROMETRIC ENZYME ELECTRODES .2. CONDUCTING SALTS AS ELECTRODE MATERIALS FOR THE OXIDATION OF GLUCOSE-OXIDASE
    ALBERY, WJ
    BARTLETT, PN
    CRASTON, DH
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1985, 194 (02): : 223 - 235
  • [3] APPLICATION OF CHRONIC INTRAVASCULAR BLOOD-GLUCOSE SENSOR IN DOGS
    ARMOUR, JC
    LUCISANO, JY
    MCKEAN, BD
    GOUGH, DA
    [J]. DIABETES, 1990, 39 (12) : 1519 - 1526
  • [4] DETERMINATION OF PHYSIOLOGICAL LEVELS OF GLUCOSE IN AN AQUEOUS MATRIX WITH DIGITALLY FILTERED FOURIER-TRANSFORM NEAR-INFRARED SPECTRA
    ARNOLD, MA
    SMALL, GW
    [J]. ANALYTICAL CHEMISTRY, 1990, 62 (14) : 1457 - 1464
  • [5] ASSOLANTVINET CH, 1986, ANAL LETT, V19, P875
  • [6] DESIGN AND INVITRO STUDIES OF A NEEDLE-TYPE GLUCOSE SENSOR FOR SUBCUTANEOUS MONITORING
    BINDRA, DS
    ZHANG, YN
    WILSON, GS
    STERNBERG, R
    THEVENOT, DR
    MOATTI, D
    REACH, G
    [J]. ANALYTICAL CHEMISTRY, 1991, 63 (17) : 1692 - 1696
  • [7] FERROCENE-MEDIATED ENZYME ELECTRODE FOR AMPEROMETRIC DETERMINATION OF GLUCOSE
    CASS, AEG
    DAVIS, G
    FRANCIS, GD
    HILL, HAO
    ASTON, WJ
    HIGGINS, IJ
    PLOTKIN, EV
    SCOTT, LDL
    TURNER, APF
    [J]. ANALYTICAL CHEMISTRY, 1984, 56 (04) : 667 - 671
  • [8] NEEDLE ENZYME ELECTRODES FOR BIOLOGICAL STUDIES
    CHURCHOUSE, SJ
    BATTERSBY, CM
    MULLEN, WH
    VADGAMA, PM
    [J]. BIOSENSORS, 1986, 2 (06) : 325 - 342
  • [9] SUBCUTANEOUS IMPLANTATION OF A FERROCENE-MEDIATED GLUCOSE SENSOR IN PIGS
    CLAREMONT, DJ
    SAMBROOK, IE
    PENTON, C
    PICKUP, JC
    [J]. DIABETOLOGIA, 1986, 29 (11) : 817 - 821
  • [10] ASSESSMENT OF SUBCUTANEOUS GLUCOSE-CONCENTRATION - VALIDATION OF THE WICK TECHNIQUE AS A REFERENCE FOR IMPLANTED ELECTROCHEMICAL SENSORS IN NORMAL AND DIABETIC DOGS
    FISCHER, U
    ERTLE, R
    ABEL, P
    REBRIN, K
    BRUNSTEIN, E
    VONDORSCHE, HH
    FREYSE, EJ
    [J]. DIABETOLOGIA, 1987, 30 (12) : 940 - 945