ANGIOGRAPHIC PREDICTORS OF RECURRENCE OF RESTENOSIS AFTER WIKTOR STENT IMPLANTATION IN NATIVE CORONARY-ARTERIES

被引:34
作者
DEJAEGERE, P
SERRUYS, PW
BERTRAND, M
WIEGAND, V
MARQUIS, JF
VROLICX, M
PIESSENS, J
VALEIX, B
KOBER, G
BONNIER, H
RUTSCH, W
UEBIS, R
机构
[1] ERASMUS UNIV ROTTERDAM,QUANTITAT ANGIOG ANAL CARDIALYSIS LAB,THORAXCTR,3000 DR ROTTERDAM,NETHERLANDS
[2] HOP CARDIOL LILLE,DEPT CARDIOL,LILLE,FRANCE
[3] UNIV GOTTINGEN,DEPT CARDIOL,W-3400 GOTTINGEN,GERMANY
[4] UNIV OTTAWA,INST HEART,DEPT CARDIOL,OTTAWA K1N 6N5,ONTARIO,CANADA
[5] UNIV HOSP CIASTHUISBERG,DEPT CARDIOL,LOUVAIN,BELGIUM
[6] CLIN LA CASAMANCE,DEPT CARDIOL,MARSEILLE,FRANCE
[7] UNIV FRANKFURT KLINIKUM,DEPT CARDIOL,FRANKFURT,GERMANY
[8] CATHARINA HOSP,DEPT CARDIOL,EINDHOVEN,NETHERLANDS
[9] UNIV HOSP BERLIN,DEPT CARDIOL,BERLIN,GERMANY
[10] RHEIN WESTFAL TH AACHEN,DEPT CARDIOL,MED CLIN 1,W-5100 AACHEN,GERMANY
关键词
D O I
10.1016/0002-9149(93)90154-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Intracoronary stenting has been proposed as an adjunct to balloon angioplasty to improve the immediate and long-term results. However, late luminal narrowing has been reported following the implantation of a variety of stents. One of the studies conducted with the Wiktor stent is a prospective registry designed to evaluate the feasibility, safety and efficacy of elective stent implantation in patients with documented restenosis of a native coronary artery. To identify angiographic variables predicting recurrence of restenosis, the angiograms of the first 91 patients with successful stent implantation and without dinical evidence of (sub)acute thrombotic stent occlusion were analyzed with the Computer Assisted Angiographic Analysis System using automated edge detection. The incidence of restenosis was 44% by patient and 45% by stent according to the 0.72 mm criterion, and 30% by patient and 29% by stent according to the 50% diameter stenosis criterion. The risk for restenosis for several angiographic variables was determined using an univariate analysis and is expressed as odds ratio with corresponding confidence interval. The only statistically significant predictor of restenosis was the relative gain when it exceeded 0.48 using the 0.72 mm criterion (odds ratio 2.7, 95% confidence interval 1.1-6.4). Furthermore, the relation between the relative gain (increase in minimal luminal diameter normalized to vessel size) as angiographic index of vessel wall injury and relative loss (decrease in minimal luminal diameter normalized to vessel size) as index of neointimal thickening was analyzed using a linear regression analysis. A Pearson product-moment correlation coefficient of 0.38 (p <0.001) was found. When using the categorical approach to address restenosis, there is an approach risk for recurrent restenosis when the relative gain exceeds 0.48, The continuous approach underscores this concept by indicating a weak but positive relation between the relative gain and relative loss.
引用
收藏
页码:165 / 170
页数:6
相关论文
共 32 条
  • [1] RESTENOSIS AFTER CORONARY ANGIOPLASTY - THE PARADOX OF INCREASED LUMEN DIAMETER AND RESTENOSIS
    BEATT, KJ
    SERRUYS, PW
    LUIJTEN, HE
    RENSING, BJ
    SURYAPRANATA, H
    DEFEYTER, P
    VANDENBRAND, M
    LAARMAN, GJ
    ROELANDT, J
    VANES, GA
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 19 (02) : 258 - 266
  • [2] REPEAT CORONARY ANGIOPLASTY - CORRELATES OF A 2ND RESTENOSIS
    BLACK, AJR
    ANDERSON, HV
    ROUBIN, GS
    POWELSON, SW
    DOUGLAS, JS
    KING, SB
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1988, 11 (04) : 714 - 718
  • [3] CLINICAL, PHYSIOLOGICAL, ANATOMIC AND PROCEDURAL FACTORS PREDICTIVE OF RESTENOSIS AFTER PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY
    BOURASSA, MG
    LESPERANCE, J
    EASTWOOD, C
    SCHWARTZ, L
    COTE, G
    KAZIM, F
    HUDON, G
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 18 (02) : 368 - 376
  • [4] CARROZZA J, 1992, CIRCULATION, V86, pA2116
  • [5] ABRUPT CORONARY-ARTERY OCCLUSION DURING PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY
    DEFEYTER, PJ
    DEJAEGERE, PPT
    MURPHY, ES
    SERRUYS, PW
    [J]. AMERICAN HEART JOURNAL, 1992, 123 (06) : 1633 - 1642
  • [6] DEJAEGERE P, 1992, CIRCULATION, V86, pA1320
  • [7] WIKTOR STENT IMPLANTATION IN PATIENTS WITH RESTENOSIS FOLLOWING BALLOON ANGIOPLASTY OF A NATIVE CORONARY-ARTERY
    DEJAEGERE, PP
    SERRUYS, PW
    BERTRAND, M
    WIEGAND, V
    KOBER, G
    MARQUIS, JF
    VALEIX, B
    UEBIS, R
    PIESSENS, J
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1992, 69 (06) : 598 - 602
  • [8] ONE-YEAR FOLLOW-UP RESULTS OF THE 1985-1986 NATIONAL-HEART-LUNG-AND-BLOOD-INSTITUTES PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY REGISTRY
    DETRE, K
    HOLUBKOV, R
    KELSEY, S
    BOURASSA, M
    WILLIAMS, D
    HOLMES, D
    DORROS, G
    FAXON, D
    MYLER, R
    KENT, K
    COWLEY, M
    CANNON, R
    ROBERTSON, T
    [J]. CIRCULATION, 1989, 80 (03) : 421 - 428
  • [9] FISCHMAN DL, 1992, RESTENOSIS INTERVENT, P191
  • [10] FOLEY DP, 1992, EUR HEART J, V13, P226