MEASUREMENT OF THE SPATIAL-RESOLUTION OF DOUBLE-SIDED DOUBLE-METAL AC-COUPLED SILICON MICROSTRIPS DETECTORS

被引:22
作者
BRENNER, R
HARR, R
RUDGE, A
SANTOS, D
STRAVER, J
WEILHAMMER, P
CZERMAK, A
GADOMSKI, S
TURALA, M
BONVICINI, V
KUCEWICZ, W
MASCIOCCHI, S
VEGNI, G
PEISERT, A
ARDELAN, J
HRISOHO, A
TROUNG, K
COUCHOT, F
COLLEDANI, C
DULINSKI, W
HUSSON, D
LOUNIS, A
MAYET, N
SCHAEFFER, M
TURCHETTA, R
SMITH, A
APSIMON, R
SELLER, P
TYNDEL, M
AALSTE, M
HIETANEN, I
LINDGREN, J
OSTERBERG, K
ORAVA, R
RONNQVIST, C
TUUVA, T
VOUTILAINEN, M
机构
[1] INST NUCL PHYS,PL-31342 KRAKOW,POLAND
[2] INFN,MILAN,ITALY
[3] UNIV MILAN,I-20122 MILAN,ITALY
[4] INFN,PADUA,ITALY
[5] LAL,ORSAY,FRANCE
[6] LEPSI,STRASBOURG,FRANCE
[7] UNIV LIVERPOOL,LIVERPOOL L69 3BX,ENGLAND
[8] RUTHERFORD APPLETON LAB,DIDCOT OX11 0QX,OXON,ENGLAND
[9] SEFT,HELSINKI,FINLAND
关键词
D O I
10.1016/0168-9002(93)90350-Q
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The design and first results from double-sided silicon microstrip detectors designed for use in the DELPHI experiment at LEP are presented. The detectors are AC-coupled on both the n- and p-side. A novel readout scheme using a second metal layer has been implemented, allowing the readout of both coordinates on the same edge of the detector. The detectors have been tested in a high energy beam at the CERN SPS. Results on spatial resolution, pulse-height correlation and charge division are presented. The spatial resolution of the n-side has been measured as a function of the beam particle incident angle from 0 to 60-degrees.
引用
收藏
页码:189 / 197
页数:9
相关论文
共 22 条
  • [1] A NEW MICROSTRIP DETECTOR WITH DOUBLE-SIDED READOUT
    AVSET, BS
    EVENSEN, L
    CHABAUD, V
    DIJKSTRA, H
    HORISBERGER, R
    HUBBELING, L
    MAEHLUM, G
    PEISERT, A
    RODITI, I
    WEILHAMMER, P
    CZERMAK, A
    JALOCHA, P
    TURALA, M
    BAMBADE, P
    DULINSKI, W
    TURCHETTA, R
    SCHAEFFER, M
    BATTAGLIA, M
    HIETANEN, I
    TUUVA, T
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1990, 37 (03) : 1153 - 1161
  • [2] OPERATIONAL EXPERIENCE WITH A LARGE DETECTOR SYSTEM USING SILICON STRIP DETECTORS WITH DOUBLE SIDED READOUT
    BATIGNANI, G
    BAUER, C
    BECKER, H
    BLOCHDEVAUX, B
    BOUDREAU, J
    BROWN, D
    BOSI, F
    BOSISIO, L
    CARPINELLI, M
    CARR, J
    CATTANEO, P
    CIOCCI, A
    COYLE, P
    DELLORSO, R
    DIETL, H
    DRINKARD, J
    FOCARDI, E
    FORTI, F
    GIORGI, M
    HANSLKOZANECKA, T
    HAUFF, D
    HOLL, P
    JACOBSEN, RG
    LANCON, E
    LAUBER, J
    LITKE, A
    LUTZ, G
    LUTJENS, G
    MANNELLI, E
    MANNER, W
    MATTISON, T
    MCNEIL, M
    MENARY, S
    MONETA, L
    MOSER, HG
    MOURS, B
    OSSA, R
    PARRINI, G
    PICCININI, S
    REDLINGER, G
    RIZZI, D
    RIZZO, G
    ROOS, L
    ROUSSEAU, D
    TAYLOR, G
    TONELLI, G
    TRIGGIANI, G
    SCHWARZ, AS
    SCHWEMLING, P
    SETTLES, R
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 326 (1-2) : 183 - 188
  • [3] BATIGNANI G, 1991, NUCL INSTRUM METH A, V310, P165
  • [4] CHARGE COLLECTION IN SILICON STRIP DETECTORS
    BELAU, E
    KLANNER, R
    LUTZ, G
    NEUGEBAUER, E
    SEEBRUNNER, HJ
    WYLIE, A
    BOHRINGER, T
    HUBBELING, L
    WEILHAMMER, P
    KEMMER, J
    KOTZ, U
    RIEBESELL, M
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 214 (2-3): : 253 - 260
  • [5] BORNER H, 1991, CERNDRDC9110
  • [6] RESULTS FROM DOUBLE-SIDED SILICON MICROSTRIP DETECTOR WITH FIELD PLATE SEPARATION
    BRENNER, R
    CARSTENS, J
    RUDGE, A
    STRAVER, J
    WEILHAMMER, P
    CZERMAK, A
    GADOMSKI, S
    JALOCHA, P
    TURALA, M
    BONVICINI, V
    PEISERT, A
    COLLEDANI, C
    DULINSKI, W
    LOUNIS, A
    SCHAEFFER, M
    TURCHETTA, R
    HARR, R
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 326 (1-2) : 198 - 203
  • [7] BRENNER R, 1992, 6TH EUR S SEM DET MI
  • [8] A SI STRIP DETECTOR WITH INTEGRATED COUPLING CAPACITORS
    CACCIA, M
    EVENSEN, L
    HANSEN, TE
    HORISBERGER, R
    HUBBELING, L
    PEISERT, A
    TUUVA, T
    WEILHAMMER, P
    ZALEWSKA, A
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1987, 260 (01) : 124 - 131
  • [9] BEAM TEST-RESULTS FROM A PROTOTYPE FOR THE DELPHI MICROVERTEX DETECTOR
    CHABAUD, V
    DIJKSTRA, H
    GRONE, M
    FLOHR, M
    HORISBERGER, R
    HUBBELING, L
    MAEHLUM, G
    PEISERT, A
    SANDVIK, A
    WEILHAMMER, P
    CZERMAK, A
    JALOCHA, P
    KAPUSTA, P
    TURALA, M
    ZALEWSKA, A
    SUNDELL, E
    TUUVA, T
    BATTAGLIA, M
    CACCIA, M
    KUCEWICZ, W
    MERONI, C
    REDAELLI, N
    TURCHETTA, R
    STOCCHI, A
    TRONCON, C
    VEGNI, G
    BARICHELLO, G
    MAZZUCATO, M
    PEGORARO, M
    SIMONETTO, F
    ALLPORT, P
    TYNDEL, M
    SEEBRUNNER, HJ
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 292 (01) : 75 - 80
  • [10] COLLEDANI C, IN PRESS CRN LEPSI N