SPECTROPHOTOMETRIC FLOW-INJECTION TECHNIQUES FOR THE MULTICOMPONENT MONITORING OF PROCESS STREAMS

被引:13
作者
MACLAURIN, P [1 ]
WORSFOLD, PJ [1 ]
机构
[1] POLYTECH SOUTH WEST, DEPT ENVIRONM SCI, PLYMOUTH PL4 8AA, DEVON, ENGLAND
关键词
D O I
10.1016/0026-265X(92)90008-Q
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An overview of simultaneous determinations in flow-injection analysis (FIA) is presented and the advantages of photodiode array detection are discussed. The application of multivariate calibration procedures to nonselective data is outlined and examples of its use in FIA are reviewed. The role of flow-injection techniques in process analysis and the potential of FIA-photodiode array-multivariate calibration systems for on-line multideterminations are also considered. © 1992.
引用
收藏
页码:178 / 188
页数:11
相关论文
共 107 条
[1]   SANDWICH TECHNIQUES IN FLOW-INJECTION ANALYSIS .2. SIMULTANEOUS DETERMINATION OF IRON(II) AND TOTAL IRON [J].
ALONSO, J ;
BARTROLI, J ;
DELVALLE, M ;
BARBER, R .
ANALYTICA CHIMICA ACTA, 1989, 219 (02) :345-350
[2]   SANDWICH TECHNIQUES IN FLOW-INJECTION ANALYSIS .1. CONTINUOUS RECALIBRATION TECHNIQUES FOR PROCESS-CONTROL [J].
ALONSO, J ;
BARTROLI, J ;
DELVALLE, M ;
ESCALADA, M ;
BARBER, R .
ANALYTICA CHIMICA ACTA, 1987, 199 :191-196
[3]   SIMULTANEOUS SPECTROFLUORIMETRIC DETERMINATION OF CERIUM(III) AND CERIUM(IV) BY FLOW-INJECTION ANALYSIS [J].
ALSOWDANI, KH ;
TOWNSHEND, A .
ANALYTICA CHIMICA ACTA, 1986, 179 :469-473
[4]  
[Anonymous], 1987, NEAR INFRARED TECHNO
[5]   SIMULTANEOUS DETERMINATION OF TOTAL IRON AND CHROMIUM(VI) IN WASTE-WATER USING A FLOW-INJECTION SYSTEM BASED ON THE SANDWICH TECHNIQUE [J].
ARAUJO, AN ;
LIMA, JLFC ;
RANGEL, AOSS ;
ALONSO, J ;
BARTROLI, J ;
BARBER, R .
ANALYST, 1989, 114 (11) :1465-1468
[6]   AN INTRODUCTION TO MULTIVARIATE CALIBRATION AND ANALYSIS [J].
BEEBE, KR ;
KOWALSKI, BR .
ANALYTICAL CHEMISTRY, 1987, 59 (17) :A1007-+
[7]   ONLINE DETERMINATION OF RESIDUAL ALUMINUM IN POTABLE AND TREATED WATERS BY FLOW-INJECTION ANALYSIS [J].
BENSON, RL ;
WORSFOLD, PJ ;
SWEETING, FW .
ANALYTICA CHIMICA ACTA, 1990, 238 (01) :177-182
[8]   CONFIGURATION WITH INTERNALLY COUPLED VALVES TO OVERCOME SHORTCOMINGS IN THE SIMULTANEOUS DETERMINATION OF NITRITE AND NITRATE BY FLOW-INJECTION ANALYSIS [J].
BERMUDEZ, B ;
RIOS, A ;
DECASTRO, MDL ;
VALCARCEL, M .
TALANTA, 1988, 35 (10) :810-812
[9]   SIMULTANEOUS DETERMINATION OF ORGANIC ISOMERS IN MIXTURES BY FLOW-INJECTION ANALYSIS WITH A DIODE-ARRAY PHOTODETECTOR [J].
BERMUDEZ, B ;
LAZARO, F ;
DECASTRO, MDL ;
VALCARCEL, M .
ANALYST, 1987, 112 (04) :535-538
[10]   DIODE-ARRAY DETECTORS IN FLOW-INJECTION ANALYSIS - MIXTURE RESOLUTION BY MULTI-WAVELENGTH ANALYSIS [J].
BLANCO, M ;
GENE, J ;
ITURRIAGA, H ;
MASPOCH, S ;
RIBA, J .
TALANTA, 1987, 34 (12) :987-993