EVALUATION OF LEFT-VENTRICULAR FUNCTION BY IMPEDANCE CARDIOGRAPHY - A REVIEW

被引:13
作者
FULLER, HD
机构
[1] MCMASTER UNIV,DEPT MED,HAMILTON,ON,CANADA
[2] MCMASTER UNIV,REG CRIT CARE PROGRAM,HAMILTON,ON,CANADA
关键词
D O I
10.1016/S0033-0620(05)80035-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
There are a number of different methods by which the impedance waveform can at least partly predict ventricular function. Of these methods, the measurement of systolic time intervals has been best validated. However, much work still needs to be done on a wide variety of ICU and non-ICU patients to validate a stable and predictable relationship between PEP/ VET and EF. Further work may also validate the other indices discussed above, but less confidence can be expressed as to their eventual clinical use at present. All of the work to date has examined the relationship between impedance and LV function. Although the impedance tracing is known to largely reflect LV ejection and aortic root flow,52 there may be some contribution from right ventricular function. To further evaluate this contribution, work using first-pass radio-nuclear techniques to selectively look at right ventricular EF will need to be done. © 1997 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:267 / 273
页数:7
相关论文
共 52 条
[1]   EVALUATION OF A CONTINUOUS, ONLINE REAL-TIME NONINVASIVE CARDIAC-OUTPUT AND EJECTION FRACTION MEASUREMENTS BY ELECTRICAL BIOIMPEDANCE IN CRITICALLY ILL PATIENTS [J].
APPEL, PL ;
BERNSTEIN, DP ;
CURTIS, DL ;
SHOEMAKER, WC ;
KRAM, HB ;
FLEMING, AW .
CRITICAL CARE MEDICINE, 1987, 15 (04) :364-364
[2]   COMPARISON OF MEASUREMENTS OF CARDIAC-OUTPUT BY BIOIMPEDANCE AND THERMODILUTION IN SEVERELY ILL SURGICAL PATIENTS [J].
APPEL, PL ;
KRAM, HB ;
MACKABEE, J ;
FLEMING, AW ;
SHOEMAKER, WC .
CRITICAL CARE MEDICINE, 1986, 14 (11) :933-935
[3]  
BERNSTEIN DP, 1985, CRIT CARE MED, V13, P355
[4]  
BERNSTEIN DP, 1986, CRIT CARE MED, V14, P989
[5]   DOES THE PULMONARY CAPILLARY WEDGE PRESSURE PREDICT LEFT-VENTRICULAR PRELOAD IN CRITICALLY ILL PATIENTS [J].
CALVIN, JE ;
DRIEDGER, AA ;
SIBBALD, WJ .
CRITICAL CARE MEDICINE, 1981, 9 (06) :437-443
[6]   MEASUREMENT OF EJECTION FRACTION BY BIOIMPEDANCE METHOD [J].
CAPAN, LM ;
BERNSTEIN, DP ;
PATEL, KP ;
SANGER, J ;
TURNDORF, H .
CRITICAL CARE MEDICINE, 1987, 15 (04) :402-402
[7]   DETERMINATION OF CARDIAC-OUTPUT DURING POSITIVE ENDEXPIRATORY PRESSURE - NONINVASIVE ELECTRICAL BIOIMPEDANCE COMPARED WITH STANDARD THERMODILUTION [J].
CASTOR, G ;
MOLTER, G ;
HELMS, J ;
NIEDERMARK, I ;
ALTMAYER, P .
CRITICAL CARE MEDICINE, 1990, 18 (05) :544-546
[8]  
CELSI A, 1989, G ITAL CARDIOL, V16, P573
[9]   COMPLICATIONS OF RIGHT HEART CATHETERIZATION - A PROSPECTIVE AUTOPSY STUDY [J].
CONNORS, AF ;
CASTELE, RJ ;
FARHAT, NZ ;
TOMASHEFSKI, JF .
CHEST, 1985, 88 (04) :567-572
[10]   COMPARISON OF TRANS-THORACIC ELECTRICAL-IMPEDANCE AND THERMODILUTION METHODS FOR MEASURING CARDIAC-OUTPUT [J].
DONOVAN, KD ;
DOBB, GJ ;
WOODS, WPD ;
HOCKINGS, BE .
CRITICAL CARE MEDICINE, 1986, 14 (12) :1038-1044