A FRACTOGRAPHIC ANALYSIS OF INVIVO POLY(METHYL METHACRYLATE) BONE-CEMENT FAILURE MECHANISMS

被引:187
作者
TOPOLESKI, LDT [1 ]
DUCHEYNE, P [1 ]
CUCKLER, JM [1 ]
机构
[1] UNIV PENN,SCH MED,DEPT ORTHOPAED,PHILADELPHIA,PA 19104
来源
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH | 1990年 / 24卷 / 02期
关键词
D O I
10.1002/jbm.820240202
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Cementing with poly(methyl methacrylate) (PMMA) is a common means of fixing total hip prostheses. Bone cement fails mechanically, and subsequent loosening frequently requires correction via revision surgery. An initial step in optimizing bone cement properties is to establish which properties are critical to the material's in vivo performance. The objectives were to discern the critical in vivo failure mechanisms of bone cement. Fracture surfaces of bone cement specimens that failed in vivo were compared with fatigue and rapid fracture surfaces created in vitro. In vivo fracture processes of bone cement were positively identified and explained by the elucidation of PMMA fracture micromechanisms. The ex vivo fracture surfaces are remarkably similar to in vitro fatigue fracture surfaces. The fractographic data document that the primary in vivo failure mechanism of bone cement is fatigue, and the fatigue cracks grow by developing a microcraze shower damage zone. Agglomerates of BaSO4 particles can be implicated in some bone cement failures, large flaws or voids in vivo can lead to a rapid, unstable fracture, pores in the PMMA mass have a clear influence on a propagating crack, and wear of the fracture surfaces occurs, and may produce PMMA debris, exacerbating bone destruction. Copyright © 1990 John Wiley & Sons, Inc.
引用
收藏
页码:135 / 154
页数:20
相关论文
共 30 条
[1]   METALLIC WEAR IN FAILED TITANIUM-ALLOY TOTAL HIP REPLACEMENTS - A HISTOLOGICAL AND QUANTITATIVE-ANALYSIS [J].
AGINS, HJ ;
ALCOCK, NW ;
BANSAL, M ;
SALVATI, EA ;
WILSON, PD ;
PELLICCI, PM ;
BULLOUGH, PG .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (03) :347-356
[2]   STRENGTH OF ACRYLIC BONE CEMENTS AND ACRYLIC CEMENT STAINLESS STEEL INTERFACES .1. STRENGTH OF ACRYLIC BONE CEMENT CONTAINING 2ND PHASE DISPERSIONS [J].
BEAUMONT, PWR .
JOURNAL OF MATERIALS SCIENCE, 1977, 12 (09) :1845-1852
[3]   SLOW CRACK GROWTH IN ACRYLIC BONE CEMENT [J].
BEAUMONT, PWR ;
YOUNG, RJ .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1975, 9 (05) :423-439
[4]  
BERRY JP, 1964, FRACTURE PROCESSES P, P157
[5]   CENTRIFUGATION AS A METHOD OF IMPROVING TENSILE AND FATIGUE PROPERTIES OF ACRYLIC BONE-CEMENT [J].
BURKE, DW ;
GATES, EI ;
HARRIS, WH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1984, 66A (08) :1265-1273
[6]   TOTAL HIP-REPLACEMENT IN PATIENTS YOUNGER THAN 30 YEARS OLD - A 5-YEAR FOLLOW-UP-STUDY [J].
CHANDLER, HP ;
REINECK, FT ;
WIXSON, RL ;
MCCARTHY, JC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1981, 63 (09) :1426-1434
[7]   2,012 TOTAL HIP ARTHROPLASTIES - STUDY OF POSTOPERATIVE COURSE AND EARLY COMPLICATIONS [J].
COVENTRY, MB ;
BECKENBAUGH, RD ;
NOLAN, DR ;
ILSTRUP, DM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1974, A 56 (02) :273-284
[8]  
DAVIES JP, 1988, CLIN ORTHOP RELAT R, V229, P156
[9]  
DOLL W, 1983, ADV POLYM SCI, V52-3, P105
[10]   MOLECULAR-WEIGHT DEPENDENT FRACTURE TRANSITION IN POLYMETHYLMETHACRYLATE [J].
DOLL, W .
JOURNAL OF MATERIALS SCIENCE, 1975, 10 (06) :935-942