ROLE OF PORTAL IMAGING IN CLINICAL RADIOTHERAPY - FLORENCE EXPERIENCE

被引:15
作者
CIONINI, L [1 ]
BUCCIOLINI, M [1 ]
机构
[1] UNIV FLORENCE,DEPT CLIN PHYSIOL & PATHOL,MED PHYS SECT,I-50134 FLORENCE,ITALY
关键词
RADIATION THERAPY; QUALITY ASSURANCE; PORTAL IMAGING; PATIENT SETUP VERIFICATION; RADIATION FIELD ALIGNMENT;
D O I
10.1016/0167-8140(93)90252-4
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
A portal imaging device developed at the Netherland's Cancer Institute (NKI) in Amsterdam was provided to the Radiotherapy Section of the University of Florence as a partner of a cooperative study on quality assurance (QUIRT) granted by the EC (AIM Project). The device was used for portal imaging in 30 patients treated for tumors of different sites (5 rectum, 6 prostate, 5 Hodgkin's lymphomas, 5 head and neck tumors, 9 other sites). Portal images were obtained three times per week over the whole treatment period. An off-line quantitative analysis of discrepancies with respect to the simulation image was performed for the 5 rectum cases; a similar analysis was also done on the portal images of 4 rectal cases treated at the NKI in Amsterdam. The analysis proved capable of demonstrating the existence of some systematic errors in both centres and the different level of global accuracy between them. The on-line use of the device was also able to demonstrate some major errors of patient setup during the first session, which were immediately corrected.
引用
收藏
页码:230 / 236
页数:7
相关论文
共 8 条
[1]   MAXIMIZING SETUP ACCURACY USING PORTAL IMAGES AS APPLIED TO A CONFORMAL BOOST TECHNIQUE FOR PROSTATIC-CANCER [J].
BIJHOLD, J ;
LEBESQUE, JV ;
HART, AAM ;
VIJLBRIEF, RE .
RADIOTHERAPY AND ONCOLOGY, 1992, 24 (04) :261-271
[2]   A REVIEW OF ELECTRONIC PORTAL IMAGING DEVICES (EPIDS) [J].
BOYER, AL ;
ANTONUK, L ;
FENSTER, A ;
VANHERK, M ;
MEERTENS, H ;
MUNRO, P ;
REINSTEIN, LE ;
WONG, J .
MEDICAL PHYSICS, 1992, 19 (01) :1-16
[3]   1ST CLINICAL-EXPERIENCE WITH A NEWLY DEVELOPED ELECTRONIC PORTAL IMAGING DEVICE [J].
MEERTENS, H ;
VANHERK, M ;
BIJHOLD, J ;
BARTELINK, H .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 18 (05) :1173-1181
[4]   A LIQUID IONIZATION DETECTOR FOR DIGITAL RADIOGRAPHY OF THERAPEUTIC MEGAVOLTAGE PHOTON BEAMS [J].
MEERTENS, H ;
VANHERK, M ;
WEEDA, J .
PHYSICS IN MEDICINE AND BIOLOGY, 1985, 30 (04) :313-321
[5]   A METHOD FOR THE MEASUREMENT OF FIELD PLACEMENT ERRORS IN DIGITAL PORTAL IMAGES [J].
MEERTENS, H ;
BIJHOLD, J ;
STRACKEE, J .
PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (03) :299-323
[6]   ACCURACY OF RADIATION-FIELD ALIGNMENT IN CLINICAL-PRACTICE [J].
RABINOWITZ, I ;
BROOMBERG, J ;
GOITEIN, M ;
MCCARTHY, K ;
LEONG, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1985, 11 (10) :1857-1867
[7]  
1984, AAPM13 AM ASS PHYS M
[8]  
1989, IEC976 INT EL COMM