SAMPLING OF POLYCHLORINATED DIBENZOFURANS (PCDF) AND DIBENZO(P)DIOXINS (PCDD) IN EMISSIONS FROM COMBUSTION FACILITIES USING AN ADSORPTION METHOD

被引:7
作者
FUNCKE, W
LINNEMANN, H
机构
[1] GfA - Gesellschaft für Arbeitsplatz- und Umweltanalytik mbH, D - 4400 Münster-Roxel
关键词
PCDD; PCDF; SAMPLING; ADSORPTION METHOD;
D O I
10.1016/0045-6535(92)90400-L
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A sampling method for PCDF/D in emissions from combustion and other industrial facilities is presented in which these substances are deposited in one collection unit consisting of a combination of quartz wool and a polymeric adsorbent (pretreated XAD-2 resin). In combination with a cooled probe, this sampling method can be used for flue gas at temperatures up to more than 1,000-degrees-C, with dust contents up to more than 1 g/m3 and water contents of more than 300 g/m3. Performance characteristics referring relative standard deviations from parallel determinations and comparison with other sampling methods are presented for PCDF/D flue gas concentrations between 2 and 0.02 ng (TE)/m3 (Toxicity equivalent according to NATO/CCMS).
引用
收藏
页码:1563 / 1572
页数:10
相关论文
共 8 条
[1]  
FUNCKE W, UNPUB
[2]  
1990, VDI3499 GUID 2
[3]  
1975, VDI GUID2066 1
[4]  
1990, VDI3499 GUID 1
[5]  
1970, VDI2449 GUID 1
[6]  
1990, VDI3499 GUID 4
[7]  
1990, VDI3499 GUID 3
[8]  
1990, 17 VER DURCHF BUND I, P2545