GLUCOSE-CONCENTRATION IN SUBCUTANEOUS EXTRACELLULAR-SPACE

被引:61
作者
SCHMIDT, FJ [1 ]
SLUITER, WJ [1 ]
SCHOONEN, AJM [1 ]
机构
[1] UNIV HOSP GRONINGEN,DIV CLIN ENDOCRINOL,GRONINGEN,NETHERLANDS
关键词
D O I
10.2337/diacare.16.5.695
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVE- To compare the subcutaneous glucose sensor measurements with two reference methods. Previous studies provide conflicting findings about the real glucose concentrations in subcutaneous tissue. Some suggest substantially lower concentration, whereas others measure proportionally higher glucose concentrations compared with the blood compartment. Before these results can be taken seriously as an expression of die real glucose concentration in the extracellular space, the measurements must be validated by an independent method. RESEARCH DESIGN AND METHODS- We applied a microdialysis-based enzyme sensor to measure glucose concentration in subcutaneous tissue. We also developed two reference methods: subcutaneous filtrate collection and an equilibration method using ultrafiltration membranes to support the earlier findings. We provided an anatomical model to explain the results. RESULTS - The mean overall intercellular filtrate glucose concentration, sampled with the filtrate collector and taken after a 6-h stabilization time, including die values during the glucose clamp period, was 46 +/- 9%. The mean subcutaneous glucose concentration measured with the glucose sensor, calibrated in vitro, was 44 +/- 8% of the mean venous blood glucose concentration. Mean overall intercellular equilibrate glucose concentration, i.e., the mean glucose concentration in the subcutaneous extracellular space, taken after a 4-h stabilization time, was 46 +/- 15% of the mean venous blood glucose concentration. CONCLUSIONS - The close agreement between the mean values of subcutaneous glucose concentrations, obtained with three independent methods-filtration, equilibration, and dialysis (sensor)-shows die real glucose concentration in subcutaneous interstitial fluid is approximately 50% the blood glucose value in normal humans. Our results clarify some of the conflicting evidence presented in previous studies.
引用
收藏
页码:695 / 700
页数:6
相关论文
共 16 条
  • [1] DEVELOPMENT OF A WEARABLE GLUCOSE SENSOR - STUDIES IN HEALTHY-VOLUNTEERS AND IN DIABETIC-PATIENTS
    AALDERS, AL
    SCHMIDT, FJ
    SCHOONEN, AJM
    BROEK, IR
    MAESSEN, AGFM
    DOORENBOS, H
    [J]. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1991, 14 (02) : 102 - 108
  • [2] ABEL P, 1984, BIOMED BIOCHIM ACTA, V43, P577
  • [3] PHYSIOLOGICAL PREPARATION FOR STUDYING THE RESPONSE OF SUBCUTANEOUSLY IMPLANTED GLUCOSE AND OXYGEN SENSORS
    ERTEFAI, S
    GOUGH, DA
    [J]. JOURNAL OF BIOMEDICAL ENGINEERING, 1989, 11 (05): : 362 - 368
  • [4] FISCHER U, 1989, ARTIF ORGANS, V13, P453
  • [5] ASSESSMENT OF SUBCUTANEOUS GLUCOSE-CONCENTRATION - VALIDATION OF THE WICK TECHNIQUE AS A REFERENCE FOR IMPLANTED ELECTROCHEMICAL SENSORS IN NORMAL AND DIABETIC DOGS
    FISCHER, U
    ERTLE, R
    ABEL, P
    REBRIN, K
    BRUNSTEIN, E
    VONDORSCHE, HH
    FREYSE, EJ
    [J]. DIABETOLOGIA, 1987, 30 (12) : 940 - 945
  • [6] CHARACTERIZATION BY MICRODIALYSIS OF INTERCELLULAR GLUCOSE LEVEL IN SUBCUTANEOUS TISSUE IN HUMANS
    JANSSON, PA
    FOWELIN, J
    SMITH, U
    LONNROTH, P
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1988, 255 (02): : E218 - E220
  • [7] A MICRODIALYSIS METHOD ALLOWING CHARACTERIZATION OF INTERCELLULAR WATER SPACE IN HUMANS
    LONNROTH, P
    JANSSON, PA
    SMITH, U
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1987, 253 (02): : E228 - E231
  • [8] MULLER A, 1986, BIOMED BIOCHIM ACTA, V45, P769
  • [9] INVIVO MOLECULAR SENSING IN DIABETES-MELLITUS - AN IMPLANTABLE GLUCOSE SENSOR WITH DIRECT ELECTRON-TRANSFER
    PICKUP, JC
    SHAW, GW
    CLAREMONT, DJ
    [J]. DIABETOLOGIA, 1989, 32 (03) : 213 - 217
  • [10] CALIBRATION OF A WEARABLE GLUCOSE SENSOR
    SCHMIDT, FJ
    AALDERS, AL
    SCHOONEN, AJM
    DOORENBOS, H
    [J]. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1992, 15 (01) : 55 - 61