MICROELECTRODE DETERMINATION OF OXYGEN PROFILES IN MICROBIAL SLIME SYSTEMS

被引:31
作者
WHALEN, WJ
BUNGAY, HR
SANDERS, WM
机构
[1] Division of Research, St. Vincent Charity Hospital, Cleveland
[2] Environmental Systems Engineering, Clemson University, Clemson
[3] Southeast Water Laboratory, USDI, Federal Water Pollution Control Administration, Athens
关键词
D O I
10.1021/es60035a004
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Dissolved oxygen profiles were measured above and within a bacterial slime mass under a continuous flow of nutrient. The microprobe tip was 1.5 μ in diameter and its location, with respect to the slime-water interface, was known to = 2 μ. With dilute media, the respiration was substrate limited and high concentrations of oxygen were found throughout the slime mass. More concentrated media increased utilization so that oxygen concentrations approached zero in the depth of the slime. © 1969, American Chemical Society. All rights reserved.
引用
收藏
页码:1297 / &
相关论文
共 2 条
[1]  
SANDERS WALTER M., 1966, AIR WATER POLLUT, V10, P253
[2]   A MICROELECTRODE FOR MEASURING INTRACELLULAR PO2 [J].
WHALEN, WJ ;
RILEY, J ;
NAIR, P .
JOURNAL OF APPLIED PHYSIOLOGY, 1967, 23 (05) :798-&