CARBON-PASTE ELECTRODES WITH INCORPORATED LACTATE OXIDASE AND MEDIATORS

被引:55
作者
KULYS, J [1 ]
SCHUHMANN, W [1 ]
SCHMIDT, HL [1 ]
机构
[1] INST BIOCHEM, VILNIUS 2600, USSR
关键词
L-LACTATE; GRAPHITE; CARBON PASTE; L-LACTATE OXIDASE; FERROCENE; 1,1'-DIMETHYLFERROCENE; N; N-DIMETHYLAMINOMETHYLFERROCENE; MELDOLA BLUE;
D O I
10.1080/00032719208020055
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Amperometric bioelectrodes based on carbon paste modified with L-lactate oxidase and mediators are described which are sensitive to L-lactate. Several ferrocenes and phenoxazine derivatives as mediators are evaluated, with Meldola blue exhibiting the best results. With ferrocene derivatives the bioelectrodes were operated at potential of 0.2-0.4 V (vs SCE). The apparent Michaelis constants for the calibration curves of the bioelectrodes are different depending on the chosen mediator and varied in the range from 0.9 to 3.6 mM L-lactate. The pH optimum in the case of the 1,1'-dimethylferrocene bioelectrode was 9.3 and the limiting sensitivity was determined to be 31-mu-A/mM cm-2. Covered by a Nafion membrane, the electrode sensitivity was in the range of 3.2-4.4-mu-A/mM cm-2 at pH 7.0 and the calibration range was linear up to 2-2.5 mM L-lactate. The bioelectrode based on Meldola blue mediated electron transfer at potentials between 0.05-0.25 V. The K(m)(app) was 17.0 and 18.2 mM at 0.1 and 0.05 V, respectively. The pH optimum of the bioelectrodes was 7.9 and limiting sensitivity - 164-mu-A/mM cm-2. At normal physiological level of ascorbic acid (50-mu-M) in blood the response of the Meldola blue based sensors was 5.3 % at 0.1 V, whereas that of the 1,1'-dimethylferrocene bioelectrode was 83 % at 0.25 V in comparison to the response observed with physiological levels of L-lactate (2 mM).
引用
收藏
页码:1011 / 1024
页数:14
相关论文
共 14 条
[1]   LONG-TERM OPERATIONAL STABILITY OF A MIXED GLUCOSE OXIDASE-REDOX MEDIATOR-CARBON PASTE ELECTRODE [J].
AMINE, A ;
KAUFFMANN, JM ;
PATRIARCHE, GJ ;
KAIFER, AE .
ANALYTICAL LETTERS, 1991, 24 (08) :1293-1315
[2]   AN AMPEROMETRIC GLUCOSE ELECTRODE BASED ON CARBON PASTE, CHEMICALLY MODIFIED WITH GLUCOSE-DEHYDROGENASE, NICOTINAMIDE ADENINE-DINUCLEOTIDE, AND A PHENOXAZINE MEDIATOR, COATED WITH A POLY(ESTER SULFONIC-ACID) CATION EXCHANGER [J].
BREMLE, G ;
PERSSON, B ;
GORTON, L .
ELECTROANALYSIS, 1991, 3 (02) :77-86
[3]   DEVICE FOR THE CONTINUOUS ASSAY OF LACTATE [J].
DURLIAT, H ;
COMTAT, M ;
MAHENC, J .
ANALYTICA CHIMICA ACTA, 1979, 106 (01) :131-135
[4]   A FLOW-INJECTION METHOD FOR THE AMPEROMETRIC DETERMINATION OF L-LACTATE WITH IMMOBILIZED ENZYMES AND A CHEMICALLY MODIFIED ELECTRODE [J].
GORTON, L ;
HEDLUND, A .
ANALYTICA CHIMICA ACTA, 1988, 213 (1-2) :91-100
[5]   BIOELECTROCHEMICAL DETECTION SYSTEMS FOR SUBSTRATES OF DEHYDROGENASES [J].
HUCK, H ;
SCHELTERGRAF, A ;
DANZER, J ;
KIRCH, P ;
SCHMIDT, HL .
ANALYST, 1984, 109 (02) :147-150
[6]   ELECTROCATALYTIC OXIDATION OF ASCORBIC-ACID AT CHEMICALLY MODIFIED ELECTRODES [J].
KULYS, J ;
DRUNGILIENE, A .
ELECTROANALYSIS, 1991, 3 (03) :209-214
[7]   CHEMICALLY MODIFIED ELECTRODES FOR THE DETERMINATION OF SULFHYDRYL COMPOUNDS [J].
KULYS, J ;
DRUNGILIENE, A .
ANALYTICA CHIMICA ACTA, 1991, 243 (02) :287-292
[8]  
KULYS J, 1991, ADV BIOSENSORS, V1, P107
[9]   AMPEROMETRIC TETRATHIAFULVALENE-MEDIATED LACTATE ELECTRODE USING LACTATE OXIDASE ABSORBED ON CARBON FOIL [J].
PALLESCHI, G ;
TURNER, APF .
ANALYTICA CHIMICA ACTA, 1990, 234 (02) :459-463
[10]  
PILLOTON R, 1988, ANAL LETT, V21, P727, DOI 10.1080/00032718808070855