We report here how magnetic resonance imaging can be used to gain definitive information about tissue pathology by the combined use of spin‐echo and gradient‐echo sequences. We also show how artifacts arising from respiratory motion can be eliminated by using a simple respiratory gating technique. © 1990 Academic Press, Inc. Copyright © 1990 Wiley‐Liss, Inc., A Wiley Company
引用
收藏
页码:121 / 127
页数:7
相关论文
共 19 条
[1]   RESPIRATORY ORDERED PHASE ENCODING (ROPE) - A METHOD FOR REDUCING RESPIRATORY MOTION ARTIFACTS IN MR IMAGING [J].
BAILES, DR ;
GILDERDALE, DJ ;
BYDDER, GM ;
COLLINS, AG ;
FIRMIN, DN .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1985, 9 (04) :835-838
[2]   ELIMINATION OF COUPLING BETWEEN CYLINDRICAL TRANSMIT COILS AND SURFACE-RECEIVE COILS FOR INVIVO NMR [J].
BENDALL, MR ;
CONNELLY, A ;
MCKENDRY, JM .
MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (01) :157-163
[3]   APPLICATION OF SPIN-ECHO NUCLEAR MAGNETIC-RESONANCE TO WHOLE-CELL SYSTEMS - MEMBRANE-TRANSPORT [J].
BRINDLE, KM ;
BROWN, FF ;
CAMPBELL, ID ;
GRATHWOHL, C ;
KUCHEL, PW .
BIOCHEMICAL JOURNAL, 1979, 180 (01) :37-44
[4]   THE EFFECT OF MAGNETIC-SUSCEPTIBILITY VARIATIONS IN NMR IMAGING AND NMR-SPECTROSCOPY INVIVO [J].
COX, IJ ;
BYDDER, GM ;
GADIAN, DG ;
YOUNG, IR ;
PROCTOR, E ;
WILLIAMS, SR ;
HART, I .
JOURNAL OF MAGNETIC RESONANCE, 1986, 70 (01) :163-168
[5]   RAPID MR IMAGING WITH SUSPENDED RESPIRATION - CLINICAL-APPLICATION IN THE LIVER [J].
EDELMAN, RR ;
HAHN, PF ;
BUXTON, R ;
WITTENBERG, J ;
FERRUCCI, JT ;
SAINI, S ;
BRADY, TJ .
RADIOLOGY, 1986, 161 (01) :125-131
[6]  
FOSTER MA, 1984, MAGNETIC RESONANCE M
[7]   LOCALIZED PROTON SPECTROSCOPY USING STIMULATED ECHOES [J].
FRAHM, J ;
MERBOLDT, KD ;
HANICKE, W .
JOURNAL OF MAGNETIC RESONANCE, 1987, 72 (03) :502-508
[8]   INTRACRANIAL HEMATOMAS - IMAGING BY HIGH-FIELD MR [J].
GOMORI, JM ;
GROSSMAN, RI ;
GOLDBERG, HI ;
ZIMMERMAN, RA ;
BILANIUK, LT .
RADIOLOGY, 1985, 157 (01) :87-93
[9]   PSEUDO-GATING - ELIMINATION OF PERIODIC MOTION ARTIFACTS IN MAGNETIC-RESONANCE-IMAGING WITHOUT GATING [J].
HAACKE, EM ;
LENZ, GW ;
NELSON, AD .
MAGNETIC RESONANCE IN MEDICINE, 1987, 4 (02) :162-174
[10]  
HELMAN RM, 1987, REV MAGN RESON MED, V2, P1