COMPUTED TOMOGRAPHIC ENHANCEMENT OF THE LIVER, LIVER-ABSCESSES, SPLEEN, AND MAJOR VESSELS WITH PERFLUOROOCTYLBROMIDE EMULSION - INFLUENCE OF DOSAGE AND INJECTION VELOCITY IN AN ANIMAL-MODEL

被引:6
作者
ADAM, G
GUNTHER, RW
SCHIFFER, C
GORTZ, H
PRESCHER, A
SCHERER, K
机构
[1] UNIV TECHNOL AACHEN,INST ANAT,AACHEN,GERMANY
[2] UNIV TECHNOL AACHEN,ANIM RES LAB,AACHEN,GERMANY
关键词
ANIMAL MODEL; COMPUTED TOMOGRAPHY; PERFLUOROOCTYLBROMIDE;
D O I
10.1097/00004424-199209000-00008
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
RATIONALE AND OBJECTIVES. Computed tomographic (CT) enhancement of the liver, liver abscess, spleen, and major vessels was investigated between 2 and 48 hours after intravenous administration of perfluorooctylbromide (PFOB emulsion) in an animal model of 63 rabbits. METHODS. Twenty-one animals received 3 g/kg PFOB as a fast bolus injection. Using a slow infusion rate, the same number of animals received either the same dose (3 g/kg) or half the dose (1.5 g/kg). RESULTS. Vascular enhancement was best after bolus injection of 3 g/kg emulsion. The density peak occurred after 2 hours. A continuous enhancement of approximately 100 Hounsfield units (HU) was observed up to 24 hours in the animals receiving 3 g/kg, independent of the injection velocity. A density peak of 70 HU was found 2 hours after the infusion of 1.5 g/kg. The density peak of the liver, the spleen, and the abscess wall was observed 48 hours after emulsion administration in all groups receiving 3 g/kg. The peak was approximately 150 HU for the liver, 400 HU for the spleen, and 150 HU for the abscess wall. In animals receiving only 1.5 g/kg perflubron, the peak density of the abscess wall was 132 HU after 12 hours, approximately 80 HU for the liver between 2 and 48 hours, and approximately 280 HU after 48 hours for the spleen. CONCLUSIONS. PFOB emulsion produces the highest vascular enhancement within the first 2 hours after the bolus injection of 3 g/kg. For spleen and abscess wall imaging, even the relatively low dose of 1.5 g/kg produced a satisfactory enhancement level for a significant length of time, whereas liver enhancement was best after administration of the higher dose.
引用
收藏
页码:698 / 705
页数:8
相关论文
共 8 条
[1]   LIVER, SPLEEN, AND VESSELS - PRELIMINARY CLINICAL-RESULTS OF CT WITH PERFLUOROOCTYLBROMIDE [J].
BRUNETON, JN ;
FALEWEE, MN ;
FRANCOIS, E ;
CAMBON, P ;
PHILIP, C ;
RIESS, JG ;
BALUMAESTRO, C ;
ROGOPOULOS, A .
RADIOLOGY, 1989, 170 (01) :179-183
[2]   PERFLUOROCTYLBROMIDE AND HEPATOSPLENIC COMPUTED-TOMOGRAPHY - PRELIMINARY CLINICAL-STUDY [J].
BRUNETON, JN ;
FALEWEE, MN ;
BALUMAESTRO, C ;
NORMAND, F ;
MATTREY, RF .
INVESTIGATIVE RADIOLOGY, 1988, 23 :S306-S307
[3]   APPLICATIONS OF PERFLUORINATED COMPOUNDS AS CONTRAST AGENTS IN COMPUTED-TOMOGRAPHY [J].
ENZMANN, D ;
YOUNG, SW .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1979, 3 (05) :622-626
[4]   PERFLUOROCTYLBROMIDE - A RETICULOENDOTHELIAL-SPECIFIC AND TUMOR-IMAGING AGENT FOR COMPUTED-TOMOGRAPHY [J].
MATTREY, RF ;
LONG, DM ;
MULTER, F ;
MITTEN, R ;
HIGGINS, CB .
RADIOLOGY, 1982, 145 (03) :755-758
[5]   SPECIFIC ENHANCEMENT OF INTRA-ABDOMINAL ABSCESSES WITH PERFLUOROCTYLBROMIDE FOR CT IMAGING [J].
MATTREY, RF ;
ANDRE, M ;
CAMPBELL, J ;
MITTEN, R ;
MULTER, F ;
HACKNEY, D ;
LONG, DM ;
HIGGINS, CB .
INVESTIGATIVE RADIOLOGY, 1984, 19 (05) :438-446
[6]   PERFLUOROCTYLBROMIDE AS A BLOOD POOL CONTRAST AGENT FOR LIVER, SPLEEN, AND VASCULAR IMAGING IN COMPUTED-TOMOGRAPHY [J].
MATTREY, RF ;
LONG, DM ;
PECK, WW ;
SLUTSKY, RA ;
HIGGINS, CB .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1984, 8 (04) :739-744
[8]  
MATTREY RF, 1992, INVEST RADIOL, V26, P792