EVALUATION OF THE SUSCEPTIBILITY EFFECT ON THE PHASE IMAGES OF A SIMPLE GRADIENT ECHO

被引:25
作者
YAMADA, N
IMAKITA, S
SAKUMA, T
NISHIMURA, Y
YAMADA, Y
NAITO, H
NISHIMURA, T
TAKAMIYA, M
机构
[1] Department of Radiology, National Cardiovascular Center, Suita, Osaka 565, 5-7-1, Fujishirodai
关键词
Brain; hemorrhage; 10.367; 10.434; Hemorrhage; MR studies; 10.1214; Magnetic resonance (MR); physics; tissue characterization;
D O I
10.1148/radiology.175.2.2326482
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The phase shifts of a simple gradient echo (fast low-angle shot) were correlated with the local change in resonance frequency due to the differences in susceptibility among tissues (susceptibility effect). Susceptibility effects were considered theoretically, and the phase shifts for spherical and cylindrical configurations were calculated. A 1.5-T magnetic resonance unit and phantoms filled with solutions of copper chloride in water were used to obtain the phase images. The phase shifts of the simple gradient echo coincided with the values calculated with use of the sum of the macroscopic magnetic field and the cavity field of Lorentz. The authors conclude that the gap of the phase shifts at interfaces of tissues is useful in the evaluation of differences in magnetic susceptibility among tissues.
引用
收藏
页码:561 / 565
页数:5
相关论文
共 12 条
[1]   THE TIME AVERAGE MAGNETIC FIELD AT THE NUCLEUS IN NUCLEAR MAGNETIC RESONANCE EXPERIMENTS [J].
DICKINSON, WC .
PHYSICAL REVIEW, 1951, 81 (05) :717-731
[2]  
EDELMAN RR, 1986, AM J NEURORADIOL, V7, P751
[3]   INTRACRANIAL HEMATOMAS - IMAGING BY HIGH-FIELD MR [J].
GOMORI, JM ;
GROSSMAN, RI ;
GOLDBERG, HI ;
ZIMMERMAN, RA ;
BILANIUK, LT .
RADIOLOGY, 1985, 157 (01) :87-93
[4]  
Ludeke K M, 1985, Magn Reson Imaging, V3, P329, DOI 10.1016/0730-725X(85)90397-2
[5]   MAGNETIC-FIELD MEASUREMENT BY NMR IMAGING [J].
MAUDSLEY, AA ;
SIMON, HE ;
HILAL, SK .
JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1984, 17 (03) :216-220
[6]  
PANOFSKY WKH, 1962, CLASSICAL ELECTRICIT
[7]  
Ronayne J, 1969, ANNUAL REV NMR SPECT, V2, P83
[8]   OXYGENATION DEPENDENCE OF THE TRANSVERSE RELAXATION-TIME OF WATER PROTONS IN WHOLE-BLOOD AT HIGH-FIELD [J].
THULBORN, KR ;
WATERTON, JC ;
MATTHEWS, PM ;
RADDA, GK .
BIOCHIMICA ET BIOPHYSICA ACTA, 1982, 714 (02) :265-270
[9]   MR IMAGING OF SUSCEPTIBILITY-INDUCED MAGNETIC-FIELD INHOMOGENEITIES [J].
WENDT, RE ;
WILCOTT, MR ;
NITZ, W ;
MURPHY, PH ;
BRYAN, RN .
RADIOLOGY, 1988, 168 (03) :837-841
[10]   HEMORRHAGIC AND NONHEMORRHAGIC BRAIN-LESIONS - EVALUATION WITH 0.35-T FAST MR IMAGING [J].
WINKLER, ML ;
OLSEN, WL ;
MILLS, TC ;
KAUFMAN, L .
RADIOLOGY, 1987, 165 (01) :203-207