A radiometric method for the determination of zinc in fire-proof dolomite is described. Matrix effects were eliminated by means of the fluorescence to scatter ratio method in combination with a copper filter. A theory of this filter method is presented. Standard deviations below 0.06% Zn were obtained. © 1979 Akadémiai Kiadó.