EVALUATION OF CATHETERS AND METALLIC CATHETER MARKERS AS CALIBRATION STANDARD FOR MEASUREMENT OF CORONARY DIMENSION

被引:43
作者
LEUNG, WH [1 ]
DEMOPULOS, PA [1 ]
ALDERMAN, EL [1 ]
SANDERS, W [1 ]
STADIUS, ML [1 ]
机构
[1] STANFORD UNIV,MED CTR,DIV CARDIOL,H2321,STANFORD,CA 94305
来源
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS | 1990年 / 21卷 / 03期
关键词
computer image processing; coronary arteriography; coronary catheters; coronary quantitation;
D O I
10.1002/ccd.1810210305
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Measurement of coronary dimension requires an accurate and reproducible dimensional reference. Angiographic catheters are frequently used for this purpose. We measured the angiographic diameters of a broad range of diagnostic and angioplasty guiding catheters by using two commonly used edge‐detection algorithms. Angiographic diameters are significantly less than true catheter outer diameter. Therefore the use of contrast‐filled catheters as a dimensional reference may lead to considerable error in vessel measurement with overestimation of absolute dimension. Tables of reference values for multiple catheters are included. We also evaluated the suitability of a metallic‐tipped “marker” catheter as calibration standard, tested under a variety of angiographic conditions. The metallic‐tipped marker was found to have a better degree of reproducibility than catheters. These findings have implications for studies employing serial measurements of coronary artery dimension and for the clinical practice of estimating vessel diameter for choice of balloon size during angioplasty. Copyright © 1990 John Wiley & Sons, Ltd.
引用
收藏
页码:148 / 153
页数:6
相关论文
共 16 条
[1]  
ALDERMAN EL, 1981, P SPIE INT SOC OPTIC, P278
[2]   ESTIMATION OF THE EFFECTS OF ANGIOPLASTY ON CORONARY STENOSIS USING QUANTITATIVE VIDEO ANGIOGRAPHY [J].
BOVE, AA ;
HOLMES, DR ;
OWEN, RM ;
BRESNAHAN, JF ;
REEDER, GS ;
SMITH, HC ;
VLIETSTRA, RE .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1985, 11 (01) :5-16
[3]   THE MECHANISMS OF NITROGLYCERIN ACTION - STENOSIS VASODILATATION AS A MAJOR COMPONENT OF THE DRUG RESPONSE [J].
BROWN, BG ;
BOLSON, E ;
PETERSEN, RB ;
PIERCE, CD ;
DODGE, HT .
CIRCULATION, 1981, 64 (06) :1089-1097
[4]   QUANTITATIVE CORONARY ARTERIOGRAPHY - ESTIMATION OF DIMENSIONS, HEMODYNAMIC RESISTANCE, AND ATHEROMA MASS OF CORONARY-ARTERY LESIONS USING ARTERIOGRAM AND DIGITAL COMPUTATION [J].
BROWN, BG ;
BOLSON, E ;
FRIMER, M ;
DODGE, HT .
CIRCULATION, 1977, 55 (02) :329-337
[5]   RELIABILITY OF ASSESSING CHANGE WITH SEQUENTIAL CORONARY ANGIOGRAPHY [J].
DETRE, KM ;
KELSEY, SF ;
PASSAMANI, ER ;
FISHER, MR ;
BRENSIKE, JF ;
BATTAGLINI, JW ;
RICHARDSON, JM ;
LOH, IK ;
STONE, NJ ;
ALDRICH, RF ;
LEVY, RI ;
EPSTEIN, SE .
AMERICAN HEART JOURNAL, 1982, 104 (04) :816-823
[6]   THE USE OF BIPLANE ANGIOCARDIOGRAPHY FOR THE MEASUREMENT OF LEFT VENTRICULAR VOLUME IN MAN [J].
DODGE, HT ;
SANDLER, H ;
BALLEW, DW ;
LORD, JD .
AMERICAN HEART JOURNAL, 1960, 60 (05) :762-776
[7]   OPTIMAL DETECTION OF THE PROGRESSION OF CORONARY-ARTERY DISEASE - COMPARISON OF METHODS SUITABLE FOR RISK FACTOR INTERVENTION TRIALS [J].
ELLIS, S ;
SANDERS, W ;
GOULET, C ;
MILLER, R ;
CAIN, KC ;
LESPERANCE, J ;
BOURASSA, MG ;
ALDERMAN, EL .
CIRCULATION, 1986, 74 (06) :1235-1242
[8]   ANGIOGRAPHIC AND CLINICAL PREDICTORS OF ACUTE CLOSURE AFTER NATIVE VESSEL CORONARY ANGIOPLASTY [J].
ELLIS, SG ;
ROUBIN, GS ;
KING, SB ;
DOUGLAS, JS ;
WEINTRAUB, WS ;
THOMAS, RG ;
COX, WR .
CIRCULATION, 1988, 77 (02) :372-379
[9]  
JACOBS JH, 1988, CATHET CARDIOVASC DI, V15, P12
[10]   CHANGES IN CROSS-SECTIONAL AREA OF THE CORONARY LUMEN IN THE 6 MONTHS AFTER ANGIOPLASTY - A QUANTITATIVE-ANALYSIS OF THE VARIABLE RESPONSE TO PERCUTANEOUS TRANS-LUMINAL ANGIOPLASTY [J].
JOHNSON, MR ;
BRAYDEN, GP ;
ERICKSEN, EE ;
COLLINS, SM ;
SKORTON, DJ ;
HARRISON, DG ;
MARCUS, ML ;
WHITE, CW .
CIRCULATION, 1986, 73 (03) :467-475