EVALUATION OF ELECTRODE POLARITY ON DEFIBRILLATION EFFICACY

被引:64
作者
BARDY, GH
IVEY, TD
ALLEN, MD
JOHNSON, G
GREENE, HL
机构
[1] UNIV WASHINGTON,DEPT MED,DIV CARDIOL,SEATTLE,WA 98195
[2] UNIV WASHINGTON,DEPT SURG,DIV CARDIOTHORAC SURG,SEATTLE,WA 98195
关键词
D O I
10.1016/0002-9149(89)90314-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:433 / 437
页数:5
相关论文
共 19 条
  • [1] INTRAOPERATIVE COMPARISON OF SEQUENTIAL-PULSE AND SINGLE-PULSE DEFIBRILLATION IN CANDIDATES FOR AUTOMATIC IMPLANTABLE DEFIBRILLATORS
    BARDY, GH
    STEWART, RB
    IVEY, TD
    GRAHAM, EL
    ADHAR, GC
    GREENE, HL
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1987, 60 (07) : 618 - 624
  • [2] PROSPECTIVE EVALUATION OF INITIALLY INEFFECTIVE DEFIBRILLATION PULSES ON SUBSEQUENT DEFIBRILLATION SUCCESS DURING VENTRICULAR-FIBRILLATION IN SURVIVORS OF CARDIAC-ARREST
    BARDY, GH
    IVEY, TD
    JOHNSON, G
    STEWART, RB
    GREENE, HL
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1988, 62 (10) : 718 - 722
  • [3] ANODAL EXCITATION OF CARDIAC MUSCLE
    CRANEFIELD, PF
    HOFFMAN, BF
    SIEBENS, AA
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1957, 190 (02): : 383 - 390
  • [4] THE EFFECTS OF CARDIOVASCULAR DRUGS ON THE DEFIBRILLATION THRESHOLD AND THE PATHOLOGICAL EFFECTS ON THE HEART USING AN AUTOMATIC IMPLANTABLE DEFIBRILLATOR
    DEEB, GM
    HARDESTY, RL
    GRIFFITH, BP
    THOMPSON, ME
    HEILMAN, MS
    MYEROWITZ, RL
    [J]. ANNALS OF THORACIC SURGERY, 1983, 35 (04) : 361 - 366
  • [5] CLINICAL-EXPERIENCE, COMPLICATIONS, AND SURVIVAL IN 70 PATIENTS WITH THE AUTOMATIC IMPLANTABLE CARDIOVERTER DEFIBRILLATOR
    ECHT, DS
    ARMSTRONG, K
    SCHMIDT, P
    OYER, PE
    STINSON, EB
    WINKLE, RA
    [J]. CIRCULATION, 1985, 71 (02) : 289 - 296
  • [6] AMIODARONE-INDUCED REFRACTORINESS TO CARDIOVERSION
    FOGOROS, RN
    [J]. ANNALS OF INTERNAL MEDICINE, 1984, 100 (05) : 699 - 700
  • [7] CARDIAC PACING AND PACEMAKERS .4. THRESHOLD OF CARDIAC STIMULATION
    FURMAN, S
    HURZELER, P
    MEHRA, R
    [J]. AMERICAN HEART JOURNAL, 1977, 94 (01) : 115 - 124
  • [8] SEQUENTIAL PULSE DEFIBRILLATION IN HUMANS - ORTHOGONAL SEQUENTIAL PULSE DEFIBRILLATION WITH EPICARDIAL ELECTRODES
    JONES, DL
    KLEIN, GJ
    GUIRAUDON, GM
    SHARMA, AD
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1988, 11 (03) : 590 - 596
  • [9] LIEM LB, 1986, CIRCULATION, V74, P483
  • [10] THE AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR - EFFICACY, COMPLICATIONS, AND DEVICE FAILURES
    MARCHLINSKI, FE
    FLORES, BT
    BUXTON, AE
    HARGROVE, WC
    ADDONIZIO, VP
    STEPHENSON, LW
    HARKEN, AH
    DOHERTY, JU
    GROGAN, EW
    JOSEPHSON, ME
    [J]. ANNALS OF INTERNAL MEDICINE, 1986, 104 (04) : 481 - 488