CORONARY ANGIOGRAPHY USING FAST SELECTIVE INVERSION RECOVERY

被引:67
作者
WANG, SJ [1 ]
HU, BS [1 ]
MACOVSKI, A [1 ]
NISHIMURA, DG [1 ]
机构
[1] STANFORD UNIV HOSP,DIV CARDIOVASC MED,STANFORD,CA 94305
关键词
D O I
10.1002/mrm.1910180216
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Using a fast version of selective inversion recovery, we have obtained coronary angiograms of normal volunteers showing the proximal portions of the left coronary artery. Blood is tagged in the aortic root at end systole using a 2D inversion pulse. After a wash‐in time of 300–600 ms, the coronary vessels are imaged with a 2‐ to 3‐cm‐thick slab in either axial or oblique projection. The scan is completed within a breathhold in 24 heartbeats. © 1991 Academic Press. Inc. Copyright © 1991 Wiley‐Liss, Inc., A Wiley Company
引用
收藏
页码:417 / 423
页数:7
相关论文
共 15 条
[1]  
BURNSTEIN D, 1990, 9TH P SMRM ANN M, V1, P80
[2]  
CHO ZH, 1990, 9TH P SMRM ANN M, V1, P63
[3]  
DUMOULIN CL, 1990, 9TH P SMRM ANN M, V1, P501
[4]   BROAD-BAND NUCLEAR MAGNETIC-RESONANCE PULSES WITH TWO-DIMENSIONAL SPATIAL SELECTIVITY [J].
HARDY, CJ ;
CLINE, HE .
JOURNAL OF APPLIED PHYSICS, 1989, 66 (04) :1513-1516
[5]  
MEYER CH, 1990, 9TH P SMRM ANN M, V1, P403
[6]   MAGNETIC-RESONANCE ANGIOGRAPHY BY SELECTIVE INVERSION RECOVERY USING A COMPACT GRADIENT ECHO SEQUENCE [J].
NISHIMURA, DG ;
MACOVSKI, A ;
JACKSON, JI ;
HU, RS ;
STEVICK, CA ;
AXEL, L .
MAGNETIC RESONANCE IN MEDICINE, 1988, 8 (01) :96-103
[7]   MR ANGIOGRAPHY BY SELECTIVE INVERSION RECOVERY [J].
NISHIMURA, DG ;
MACOVSKI, A ;
PAULY, JM ;
CONOLLY, SM .
MAGNETIC RESONANCE IN MEDICINE, 1987, 4 (02) :193-202
[8]   CONSIDERATIONS OF MAGNETIC-RESONANCE ANGIOGRAPHY BY SELECTIVE INVERSION RECOVERY [J].
NISHIMURA, DG ;
MACOVSKI, A ;
PAULY, JM .
MAGNETIC RESONANCE IN MEDICINE, 1988, 7 (04) :472-484
[9]  
NISHIMURA DG, 1988, 7TH P SMRM ANN M, V1, P403
[10]  
PASCHAL CB, 1990, 9TH P SMRM ANN M, V1, P278