THE DEPENDENCE OF EIT IMAGES ON THE ASSUMED INITIAL CONDUCTIVITY DISTRIBUTION - A STUDY OF PELVIC IMAGING

被引:15
作者
MEESON, S
KILLINGBACK, ALT
BLOTT, BH
机构
[1] Dept. of Phys., Southampton Univ.
关键词
D O I
10.1088/0031-9155/40/4/010
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
EIT measurements on humans are often made in regions of the body where the conductivity distribution is far from uniform. This paper addresses the problem of deriving accurate quantitative data in one such region: the conductivity changes associated with the accumulation of blood in the pelvic bowl. A computer map of the bone in the pelvic region was constructed, from which an appropriate reconstruction matrix was generated. Both computer simulations and tank tests were performed to assess whether this bone reconstruction matrix produced impedance images with closer fidelity to the measured object than images produced using a reconstruction based on a uniform conductivity distribution. As expected, images produced by the computer simulation indicated that the bone reconstruction matrix produced images of better fidelity than did the uniform reconstruction matrix. However, in the case of the tank data only a moderate improvement was achieved. The reconstruction matrix based on a uniform conductivity distribution was found to produce satisfactory images for both bone and near-uniform objects, but for regions further into the pelvic bowl, where the signal was lower, the uniform reconstruction matrix was less satisfactory.
引用
收藏
页码:643 / 657
页数:15
相关论文
共 12 条
[1]   APPLIED POTENTIAL TOMOGRAPHY [J].
BARBER, DC ;
BROWN, BH .
JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1984, 17 (09) :723-733
[2]  
DIJKSTRA AM, 1993, J MED ENG TECHNOL, V13, P89
[3]   SINGULAR VALUE DECOMPOSITION AND LEAST SQUARES SOLUTIONS [J].
GOLUB, GH ;
REINSCH, C .
NUMERISCHE MATHEMATIK, 1970, 14 (05) :403-&
[4]  
KILLINGBACK ALT, 1993, CLIN PHYSL APPLICATI, P229
[5]   UNDERSTANDING INVERSE THEORY [J].
PARKER, RL .
ANNUAL REVIEW OF EARTH AND PLANETARY SCIENCES, 1977, 5 :35-64
[6]  
SPIEGEL MR, 1981, SCHAUMS OUTLINE SERI, P200
[7]   WHISTLER INVERSION BY SPECTRAL EXPANSION [J].
TARCSAI, G ;
DANIELL, GJ .
JOURNAL OF ATMOSPHERIC AND TERRESTRIAL PHYSICS, 1979, 41 (09) :967-981
[8]   CORRECTION OF THE NONUNIFORM SPATIAL SENSITIVITY OF ELECTRICAL-IMPEDANCE TOMOGRAPHY IMAGES [J].
THOMAS, DC ;
SIDDALLALLUM, JN ;
SUTHERLAND, IA ;
BEARD, RW .
PHYSIOLOGICAL MEASUREMENT, 1994, 15 :A147-A152
[9]  
THOMAS DC, 1993, CLINICAL AND PHYSIOLOGICAL APPLICATIONS OF ELECTRICAL IMPEDANCE TOMOGRAPHY, P227
[10]  
ZADEHKOCHAK M, 1991, THESIS U SOUTHAMPTON